C8051F560-TB Silicon Laboratories Inc, C8051F560-TB Datasheet - Page 232

BOARD PROTOTYPE W/C8051F560

C8051F560-TB

Manufacturer Part Number
C8051F560-TB
Description
BOARD PROTOTYPE W/C8051F560
Manufacturer
Silicon Laboratories Inc
Type
MCUr
Datasheet

Specifications of C8051F560-TB

Contents
Board
Processor To Be Evaluated
C8051F56x
Processor Series
C8051F56x
Interface Type
USB
Maximum Operating Temperature
+ 125 C
Minimum Operating Temperature
- 40 C
Operating Supply Voltage
1.8 V to 5.25 V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With/related Products
C8051F55x, C8051F56x, C8051F57x
For Use With
336-1691 - KIT DEVELOPMENT FOR C8051F560
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
336-1694
C8051F55x/56x/57x
232
Values Read
0100 0 0 0 A slave byte was transmitted;
0101 0 X X An illegal STOP or bus error
0010 1 0 X A slave address + R/W was
0001 0 0 X A STOP was detected while
0000 1 0 X A slave byte was received;
0010 0 1 X Lost arbitration while attempt-
0001 0 1 X Lost arbitration due to a
0000 1 1 X Lost arbitration while transmit-
0 0 1 A slave byte was transmitted;
0 1 X A Slave byte was transmitted;
1 1 X Lost arbitration as master;
1 1 X Lost arbitration while attempt-
Current SMbus State
NACK received.
ACK received.
error detected.
was detected while a Slave
Transmission was in progress.
received; ACK requested.
slave address + R/W received;
ACK requested.
addressed as a Slave Trans-
mitter or Slave Receiver.
ing a STOP.
ACK requested.
ing a repeated START.
detected STOP.
ting a data byte as master.
Table 22.4. SMBus Status Decoding (Continued)
Rev. 1.1
Typical Response Options
No action required (expecting
STOP condition).
Load SMB0DAT with next data
byte to transmit.
No action required (expecting
Master to end transfer).
Clear STO.
If Write, Acknowledge received
address
If Read, Load SMB0DAT with
data byte; ACK received address
NACK received address.
If Write, Acknowledge received
address
If Read, Load SMB0DAT with
data byte; ACK received address
NACK received address.
Reschedule failed transfer;
NACK received address.
Clear STO.
No action required (transfer
complete/aborted).
Acknowledge received byte;
Read SMB0DAT.
NACK received byte.
Abort failed transfer.
Reschedule failed transfer.
Abort failed transfer.
Reschedule failed transfer.
Abort failed transfer.
Reschedule failed transfer.
Values to
Write
0 0 X 0001
0 0 X 0100
0 0 X 0001
0 0 X
0 0 1
0 0 1
0 0 0
0 0 1
0 0 1
0 0 0
1 0 0
0 0 X
0 0 0
0 0 1
0 0 0
0 0 X
1 0 X
0 0 X
1 0 X
0 0 0
1 0 0
0000
0100
0000
0100
0000
1110
1110
1110