5 Working with HC08 Devices
5.1 Debugging Limitations
Since inDART-One is based on the in-chip debugging features of the HC08
family of microcontrollers, some hardware and software limitations apply.
The main ones are listed below; for the complete list of limitations please
refer to the microcontroller’s data sheet.
5.2 Communication Settings
inDART-One must be configured properly so that MON08 communication
with the target device can be established correctly.
The pin dedicated to the host communication is reserved—in particular,
the corresponding bit in the Data Direction Register must not be
changed (must be left to input);
The Break Module peripheral is reserved, and only one hardware
breakpoint is available—however, you can insert a “swi” instruction
into your code to generate a software breakpoint;
The “swi” instruction is reserved and can be only used to generate a
software breakpoint;
Step commands which involve the execution of two or more Assembly
instructions waste one hardware breakpoint—therefore, if one
breakpoint was already set by the user, the step command cannot be
executed;
The “Halt” debugging command (in the CodeWarrior HC08 user
interface) will not work unless the IRQ interrupt is properly handled;
13 bytes of stack are wasted by the on-chip monitor—therefore the
addresses from SP-13 to SP are reserved;
Registers which affect the target microcontroller’s clock speed must not
be changed during debugging sessions.