PIC18F65K90T-I/PT Microchip Technology, PIC18F65K90T-I/PT Datasheet - Page 357

32kB Flash, 2kB RAM, 1kB EE, NanoWatt XLP, LCD 64 TQFP 10x10x1mm T/R

PIC18F65K90T-I/PT

Manufacturer Part Number
PIC18F65K90T-I/PT
Description
32kB Flash, 2kB RAM, 1kB EE, NanoWatt XLP, LCD 64 TQFP 10x10x1mm T/R
Manufacturer
Microchip Technology
Series
PIC® XLP™ 18Fr
Datasheet

Specifications of PIC18F65K90T-I/PT

Processor Series
PIC18F
Core
PIC
Data Bus Width
8 bit
Program Memory Type
Flash
Program Memory Size
32 KB
Data Ram Size
2 KB
Interface Type
I2C, SPI
Maximum Clock Frequency
64 MHz
Number Of Timers
8
Operating Supply Voltage
1.8 V to 5.5 V
Maximum Operating Temperature
+ 125 C
3rd Party Development Tools
52715-96, 52716-328, 52717-734, 52712-325, EWPIC18
Minimum Operating Temperature
- 40 C
On-chip Adc
12 bit, 16 Channel
Core Processor
PIC
Core Size
8-Bit
Speed
64MHz
Connectivity
I²C, LIN, SPI, UART/USART
Peripherals
Brown-out Detect/Reset, LCD, POR, PWM, WDT
Number Of I /o
53
Eeprom Size
1K x 8
Ram Size
2K x 8
Voltage - Supply (vcc/vdd)
1.8 V ~ 5.5 V
Data Converters
A/D 16x12b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
64-TQFP
Lead Free Status / Rohs Status
 Details

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PIC18F65K90T-I/PT
Manufacturer:
Microchip Technology
Quantity:
10 000
Part Number:
PIC18F65K90T-I/PTRSL
Manufacturer:
Microchip Technology
Quantity:
10 000
22.1.3
The Enhanced USART module supports the automatic
detection and calibration of baud rate. This feature is
active only in Asynchronous mode and while the WUE
bit is clear.
The automatic baud rate measurement sequence
(Figure
and the ABDEN bit is set. The calculation is
self-averaging.
In the Auto-Baud Rate Detect (ABD) mode, the clock to
the BRG is reversed. Rather than the BRG clocking the
incoming RXx signal, the RXx signal is timing the BRG.
In ABD mode, the internal Baud Rate Generator is
used as a counter to time the bit period of the incoming
serial byte stream.
Once the ABDEN bit is set, the state machine will clear
the BRG and look for a Start bit. The Auto-Baud Rate
Detect must receive a byte with the value, 55h (ASCII
“U”, which is also the LIN/J2602 bus Sync character), in
order to calculate the proper bit rate. The measurement
is taken over both a low and a high bit time in order to
minimize any effects caused by asymmetry of the incom-
ing signal. After a Start bit, the SPBRGx begins counting
up, using the preselected clock source on the first rising
edge of RXx. After eight bits on the RXx pin or the fifth
rising edge, an accumulated value totalling the proper
BRG period is left in the SPBRGHx:SPBRGx register
pair. Once the 5th edge is seen (this should correspond
to the Stop bit), the ABDEN bit is automatically cleared.
If a rollover of the BRG occurs (an overflow from FFFFh
to 0000h), the event is trapped by the ABDOVF status
bit (BAUDCONx<7>). It is set in hardware by BRG roll-
overs and can be set or cleared by the user in software.
ABD mode remains active after rollover events and the
ABDEN bit remains set
While calibrating the baud rate period, the BRG
registers are clocked at 1/8th the preconfigured clock
rate. Note that the BRG clock can be configured by the
BRG16 and BRGH bits. The BRG16 bit must be set to
use both SPBRG1 and SPBRGH1 as a 16-bit counter.
This allows the user to verify that no carry occurred for
8-bit modes by checking for 00h in the SPBRGHx
register. Refer to
the BRG.
 2009-2011 Microchip Technology Inc.
22-1) begins whenever a Start bit is received
AUTO-BAUD RATE DETECT
Table 22-4
(Figure
for counter clock rates to
22-2).
PIC18F87K90 FAMILY
While the ABD sequence takes place, the EUSART
state machine is held in Idle. The RCxIF interrupt is set
once the fifth rising edge on RXx is detected. The value
in the RCREGx needs to be read to clear the RCxIF
interrupt. The contents of RCREGx should be
discarded.
TABLE 22-4:
22.1.3.1
Since the BRG clock is reversed during ABD acquisi-
tion, the EUSART transmitter cannot be used during
ABD. This means that whenever the ABDEN bit is set,
TXREGx cannot be written to. Users should also
ensure that ABDEN does not become set during a
transmit sequence. Failing to do this may result in
unpredictable EUSART operation.
BRG16
Note 1: If the WUE bit is set with the ABDEN bit,
0
0
1
1
2: It is up to the user to determine that the
3: To maximize baud rate range, it is
BRGH
system timing and communication baud
Auto-Baud Rate Detection will occur on
the byte following the Break character.
incoming character baud rate is within the
range of the selected BRG clock source.
Some combinations of oscillator fre-
quency and EUSART baud rates are not
possible due to bit error rates. Overall
rates must be taken into consideration
when using the Auto-Baud Rate Detection
feature.
recommended
(BAUDCONx<3>) bit if the auto-baud
feature is used.
ABD and EUSART Transmission
0
1
0
1
BRG COUNTER
CLOCK RATES
BRG Counter Clock
to
F
F
F
F
OSC
OSC
OSC
OSC
set
DS39957D-page 357
/512
/128
/128
/32
the
BRG16

Related parts for PIC18F65K90T-I/PT