SAM3SD8C Atmel Corporation, SAM3SD8C Datasheet - Page 768

no-image

SAM3SD8C

Manufacturer Part Number
SAM3SD8C
Description
Manufacturer
Atmel Corporation
Datasheets
• RX_PP: Receiver Preamble Pattern detected
The following values assume that RX_MPOL field is not set:
• RX_MPOL: Receiver Manchester Polarity
0: Logic Zero is coded as a zero-to-one transition, Logic One is coded as a one-to-zero transition.
1: Logic Zero is coded as a one-to-zero transition, Logic One is coded as a zero-to-one transition.
• DRIFT: Drift compensation
0: The USART can not recover from an important clock drift
1: The USART can recover from clock drift. The 16X clock mode must be enabled.
768
768
Value
00
01
10
11
SAM3S8/SD8
SAM3S8/SD8
Name
ALL_ONE
ALL_ZERO
ZERO_ONE
ONE_ZERO
Description
The preamble is composed of ‘1’s
The preamble is composed of ‘0’s
The preamble is composed of ‘01’s
The preamble is composed of ‘10’s
11090A–ATARM–10-Feb-12