PCM18XK1 Microchip Technology, PCM18XK1 Datasheet - Page 214

MODULE PROC PIC18F8680,6680,8565

PCM18XK1

Manufacturer Part Number
PCM18XK1
Description
MODULE PROC PIC18F8680,6680,8565
Manufacturer
Microchip Technology
Datasheet

Specifications of PCM18XK1

Accessory Type
Processor Module
Lead Free Status / RoHS Status
Not applicable / Not applicable
For Use With/related Products
ICE2000
For Use With
ICE2000 - EMULATOR MPLAB-ICE 2000 POD
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
PIC18F6585/8585/6680/8680
17.4.5
The addressing procedure for the I
the first byte after the Start condition usually
determines which device will be the slave addressed by
the master. The exception is the general call address
which can address all devices. When this address is
used, all devices should, in theory, respond with an
Acknowledge.
The general call address is one of eight addresses
reserved for specific purposes by the I
consists of all ‘0’s with R/W = 0.
The general call address is recognized when the Gen-
eral Call Enable bit (GCEN) is enabled (SSPCON2<7>
is set). Following a Start bit detect, 8 bits are shifted into
the SSPSR and the address is compared against the
SSPADD. It is also compared to the general call
address and fixed in hardware.
FIGURE 17-15:
DS30491C-page 212
GCEN (SSPCON2<7>)
SSPOV (SSPCON1<6>)
SDA
SCL
SSPIF
BF (SSPSTAT<0>)
GENERAL CALL ADDRESS
SUPPORT
S
SLAVE MODE GENERAL CALL ADDRESS SEQUENCE
(7 OR 10-BIT ADDRESS MODE)
1
2
General Call Address
2
C bus is such that
3
2
4
C protocol. It
5
6
7
R/W = 0
8
If the general call address matches, the SSPSR is
transferred to the SSPBUF, the BF flag bit is set (eighth
bit) and on the falling edge of the ninth bit (ACK bit), the
SSPIF interrupt flag bit is set.
When the interrupt is serviced, the source for the inter-
rupt can be checked by reading the contents of the
SSPBUF. The value can be used to determine if the
address was device specific or a general call address.
In 10-bit mode, the SSPADD is required to be updated
for the second half of the address to match and the UA
bit is set (SSPSTAT<1>). If the general call address is
sampled when the GCEN bit is set while the slave is
configured in 10-bit Address mode, then the second
half of the address is not necessary, the UA bit will not
be set and the slave will begin receiving data after the
Acknowledge (Figure 17-15).
ACK
Address is compared to General Call Address
after ACK, set interrupt
9
D7
1
D6
2
Cleared in software
SSPBUF is read
Receiving Data
D5
3
D4
4
 2004 Microchip Technology Inc.
D3
5
D2
6
D1
7
D0
8
ACK
9
‘0’
‘1’

Related parts for PCM18XK1