S9S12P64J0MFT Freescale Semiconductor, S9S12P64J0MFT Datasheet - Page 320

no-image

S9S12P64J0MFT

Manufacturer Part Number
S9S12P64J0MFT
Description
MCU 64K FLASH AUTO 48-QFN
Manufacturer
Freescale Semiconductor
Series
HCS12r
Datasheet

Specifications of S9S12P64J0MFT

Core Processor
HCS12
Core Size
16-Bit
Speed
32MHz
Connectivity
CAN, SCI, SPI
Peripherals
LVD, POR, PWM, WDT
Number Of I /o
34
Program Memory Size
64KB (64K x 8)
Program Memory Type
FLASH
Eeprom Size
4K x 8
Ram Size
4K x 8
Voltage - Supply (vcc/vdd)
1.72 V ~ 5.5 V
Data Converters
A/D 10x12b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 125°C
Package / Case
48-QFN Exposed Pad
Processor Series
S12P
Core
HCS12
3rd Party Development Tools
EWHCS12
Development Tools By Supplier
KIT33812ECUEVME, DEMO9S12PFAME
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
S9S12P64J0MFT
0
Analog-to-Digital Converter (ADC12B10C)
Read: Anytime
Write: Anytime (No effect on (CC3, CC2, CC1, CC0))
9.3.2.8
Writes to this register will abort current conversion sequence.
Read: Anytime
Write: Anytime
320
ETORF
CC[3:0]
FIFOR
Field
SCF
3–0
7
5
4
Sequence Complete Flag — This flag is set upon completion of a conversion sequence. If conversion
sequences are continuously performed (SCAN=1), the flag is set after each one is completed. This flag is cleared
when one of the following occurs:
0 Conversion sequence not completed
1 Conversion sequence has completed
External Trigger Overrun Flag — While in edge trigger mode (ETRIGLE=0), if additional active edges are
detected while a conversion sequence is in process the overrun flag is set. This flag is cleared when one of the
following occurs:
0 No External trigger over run error has occurred
1 External trigger over run error has occurred
Result Register Over Run Flag — This bit indicates that a result register has been written to before its
associated conversion complete flag (CCF) has been cleared. This flag is most useful when using the FIFO mode
because the flag potentially indicates that result registers are out of sync with the input channels. However, it is
also practical for non-FIFO modes, and indicates that a result register has been over written before it has been
read (i.e. the old data has been lost). This flag is cleared when one of the following occurs:
0 No over run has occurred
1 Overrun condition exists (result register has been written while associated CCFx flag was still set)
Conversion Counter — These 4 read-only bits are the binary value of the conversion counter. The conversion
counter points to the result register that will receive the result of the current conversion. E.g. CC3=0, CC2=1,
CC1=1, CC0=0 indicates that the result of the current conversion will be in ATD Result Register 6. If in non-FIFO
mode (FIFO=0) the conversion counter is initialized to zero at the begin and end of the conversion sequence. If
in FIFO mode (FIFO=1) the register counter is not initialized. The conversion counters wraps around when its
maximum value is reached.
Aborting a conversion or starting a new conversion clears the conversion counter even if FIFO=1.
ATD Compare Enable Register (ATDCMPE)
A) Write “1” to ETORF
B) Write to ATDCTL0,1,2,3,4, ATDCMPE or ATDCMPHT (a conversion sequence is aborted)
C) Write to ATDCTL5 (a new conversion sequence is started)
A) Write “1” to FIFOR
B) Write to ATDCTL0,1,2,3,4, ATDCMPE or ATDCMPHT (a conversion sequence is aborted)
C) Write to ATDCTL5 (a new conversion sequence is started)
A) Write “1” to SCF
B) Write to ATDCTL5 (a new conversion sequence is started)
C) If AFFC=1 and read of a result register
Table 9-16. ATDSTAT0 Field Descriptions
S12P-Family Reference Manual, Rev. 1.13
Description
Freescale Semiconductor

Related parts for S9S12P64J0MFT