C8051F537-IT Silicon Laboratories Inc, C8051F537-IT Datasheet - Page 203

IC 8051 MCU 2K FLASH 20TSSOP

C8051F537-IT

Manufacturer Part Number
C8051F537-IT
Description
IC 8051 MCU 2K FLASH 20TSSOP
Manufacturer
Silicon Laboratories Inc
Series
C8051F53xr
Datasheets

Specifications of C8051F537-IT

Core Processor
8051
Core Size
8-Bit
Speed
25MHz
Connectivity
SPI, UART/USART
Peripherals
Brown-out Detect/Reset, POR, PWM, Temp Sensor, WDT
Number Of I /o
16
Program Memory Size
2KB (2K x 8)
Program Memory Type
FLASH
Ram Size
256 x 8
Voltage - Supply (vcc/vdd)
2 V ~ 5.25 V
Data Converters
A/D 16x12b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 125°C
Package / Case
20-TSSOP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Other names
336-1401

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
C8051F537-IT
Manufacturer:
Silicon Labs
Quantity:
135
19.3.1. Watchdog Timer Operation
While the WDT is enabled:
While the WDT is enabled, writes to the CR bit will not change the PCA counter state; the counter will run
until the WDT is disabled. The PCA counter run control (CR) will read zero if the WDT is enabled but user
software has not enabled the PCA counter. If a match occurs between PCA0CPH2 and PCA0H while the
WDT is enabled, a reset will be generated. To prevent a WDT reset, the WDT may be updated with a write
of any value to PCA0CPH2. Upon a PCA0CPH2 write, PCA0H plus the offset held in PCA0CPL2 is loaded
into PCA0CPH2 (See Figure 19.10).
Note that the 8-bit offset held in PCA0CPH2 is compared to the upper byte of the 16-bit PCA counter. This
offset value is the number of PCA0L overflows before a reset. Up to 256 PCA clocks may pass before the
first PCA0L overflow occurs, depending on the value of the PCA0L when the update is performed. The
total offset is then given (in PCA clocks) by Equation 19.4, where PCA0L is the value of the PCA0L register
at the time of the update.
The WDT reset is generated when PCA0L overflows while there is a match between PCA0CPH2 and
PCA0H. Software may force a WDT reset by writing a 1 to the CCF2 flag (PCA0CN.2) while the WDT is
enabled.
PCA counter is forced on.
Writes to PCA0L and PCA0H are not allowed.
PCA clock source bits (CPS2-CPS0) are frozen.
PCA Idle control bit (CIDL) is frozen.
Module 2 is forced into software timer mode.
Writes to the Module 2 mode register (PCA0CPM2) are disabled.
PCA0CPL2
C
D
L
I
W
D
T
E
PCA0MD
W
D
C
K
L
PCA0CPH2
C
P
S
2
Figure 19.10. PCA Module 2 with Watchdog Timer Enabled
Write to
C
P
S
1
C
P
S
0
Equation 19.4. Watchdog Timer Offset in PCA Clocks
E
C
F
Offset
8-bit Adder
=
Enable
Adder
256 PCA0CPL2
C8051F52x/F52xA/F53x/F53xA
Enable
Rev. 1.3
PCA0CPH2
Comparator
PCA0H
8-bit
+
256 PCA0L
Match
PCA0L Overflow
Reset
203