XBP24-PKI-001-RA Digi International/Maxstream, XBP24-PKI-001-RA Datasheet - Page 38

no-image

XBP24-PKI-001-RA

Manufacturer Part Number
XBP24-PKI-001-RA
Description
MODULE 802.15.4 RS-232 ANT
Manufacturer
Digi International/Maxstream
Series
XBEE-PRO™r

Specifications of XBP24-PKI-001-RA

Frequency
2.4GHz
Data Rate - Maximum
250kbps
Modulation Or Protocol
802.15.4
Applications
Home/Building Automation, Industrial Control, ZigBee™
Power - Output
0dBm
Sensitivity
-92dBm
Voltage - Supply
2.8 V ~ 3.4 V
Current - Receiving
55mA
Data Interface
Connector, Female DB-9
Antenna Connector
RP-SMA
Operating Temperature
-40°C ~ 85°C
Package / Case
Module
Memory Size
-
Current - Transmitting
-
Other names
Q3255595
© 2008 Digi International, Inc. 
XBee‐PRO PKG‐R® RS‐232 RF Modem – 802.15.4 ‐ Product Manual v1.xAx 
DL (Destination Address Low) Command
DN (Destination Node) Command
DP (Disassociation Cyclic Sleep Period) Command
EA (ACK Failures) Command
<Networking {Addressing}> The DL command is
used to set and read the lower 32 bits of the RF
modem's 64-bit destination address. When
combined with the DH (Destination Address High)
parameter, it defines the destination address
used for transmission.
A modem will only communicate with other
modems having the same channel (CH
parameter), PAN ID (ID parameter) and destination address (DH + DL parameters).
To transmit using a 16-bit address, set the DH parameter to zero and the DL parameter less than
0xFFFF. 0x000000000000FFFF (DL concatenated to DH) is the broadcast address for the PAN.
Refer to the XBee/XBee-PRO Addressing section for more information.
<Networking {Identification}> The DN command
is used to resolve a NI (Node Identifier) string to
a physical address. The following events occur
upon successful command execution:
modem with the matching NI (Node Identifier).
If there is no response from a modem within 200 msec or a parameter is not specified (left blank),
the command is terminated and an ‘ERROR’ message is returned.
<Sleep Mode (Low Power)>
NonBeacon Firmware
End Device - The DP command is used to set and
read the time period of sleep for cyclic sleeping
remotes that are configured for Association but
are not associated to a Coordinator. (i.e. If a
device is configured to associate, configured as a
Cyclic Sleep remote, but does not find a
Coordinator; it will sleep for DP time before
reattempting association.) Maximum sleep period
is 268 seconds (0x68B0). DP should be > 0 for NonBeacon systems.
<Diagnostics> The EA command is used to reset
and read the count of ACK (acknowledgement)
failures. This parameter value increments when
the modem expires its transmission retries
without receiving an ACK on a packet
transmission. This count saturates at its maximum value.
Set the parameter to “0” to reset count.
1. DL and DH are set to the address of the
2. ‘OK’ is returned.
3. RF modem automatically exits AT Command Mode.
AT Command: ATDP
Parameter Range: 1 - 0x68B0
Default Parameter Value:0x3E8
Related Commands: SM (Sleep Mode), SP
(Cyclic Sleep Period), ST (Time before Sleep)
Minimum Firmware Version Required: v1.x80
AT Command: ATEA
Parameter Range:0 - 0xFFFF
Minimum Firmware Version Required: v1.x80
AT Command: ATDL
Parameter Range: 0 - 0xFFFFFFFF
Default Parameter Value: 0
Related Commands: DH (Destination Address
High), CH (Channel), ID (PAN VID), MY (Source
Address)
AT Command: ATDN
Parameter Range: 20-character ASCII String
Minimum Firmware Version Required: v1.x80
[x 10 milliseconds]
(1000 decimal)
     38