Specifications of XBP24-PKI-001-RA

Frequency
2.4GHz
Data Rate - Maximum
250kbps
Modulation Or Protocol
802.15.4
Applications
Home/Building Automation, Industrial Control, ZigBee™
Power - Output
0dBm
Sensitivity
-92dBm
Voltage - Supply
2.8 V ~ 3.4 V
Current - Receiving
55mA
Data Interface
Connector, Female DB-9
Antenna Connector
RP-SMA
Operating Temperature
-40°C ~ 85°C
Package / Case
Module
Memory Size
-
Current - Transmitting
-
Other names
Q3255595
© 2008 Digi International, Inc. 
XBee‐PRO PKG‐R® RS‐232 RF Modem – 802.15.4 ‐ Product Manual v1.xAx 
IO (Digital Output Level) Command
IR (Sample Rate) Command
IS (Force Sample) Command
IT (Samples before TX) Command
<I/O Settings> The IO command is used to set
digital output levels. This allows DIO lines setup
as outputs to be changed through Command
Mode.
<I/O Settings> The IR command is used to set/
read the sample rate. When set, the module will
sample all enabled DIO/ADC lines at a specified
interval. This command allows periodic reads of
the ADC and DIO lines in a non-Sleep Mode
setup.
Example: When IR = 0x0A, the sample rate is 10
ms (or 100 Hz).
<I/O Settings> The IS command is used to force
a read of all enabled DIO/ADC lines. The data is
returned through the UART.
When operating in Transparent Mode (AP=0), the
data is retuned in the following format:
All bytes are converted to ASCII:
When operating in API mode (AP > 0), the command will immediately return an ‘OK’ response.
The data will follow in the normal API format for DIO data.
<I/O Settings> The IT command is used to set/
read the number of DIO and ADC samples to
collect before transmitting data.
One ADC sample is considered complete when all
enabled ADC channels have been read. The
modem can buffer up to 93 Bytes of sample data.
Since the modem uses a 10-bit A/D converter, each sample uses two Bytes. This leads to a
maximum buffer size of 46 samples or IT=0x2E.
When Sleep Modes are enabled and IR (Sample Rate) is set, the modem will remain awake until IT
samples have been collected.
number of samples<CR>
channel mask<CR>
DIO data<CR> (If DIO lines are enabled<CR>
ADC channel Data<cr> <-This will repeat for every enabled ADC channel<CR>
<CR> (end of data noted by extra <CR>)
AT Command: ATIO
Parameter Range: 8-bit bitmap
(where each bit represents the level of an I/O
line that is setup as an output.)
Minimum Firmware Version Required: v1.xA0
AT Command: ATIR
Parameter Range: 0 - 0xFFFF [x 1 msec]
(cannot guarantee 1 ms timing when IT=1)
Default Parameter Value:0
Related Command: IT (Samples before TX)
Minimum Firmware Version Required: v1.xA0
AT Command: ATIS
Parameter Range: 1 - 0xFF
Default Parameter Value:1
Minimum Firmware Version Required: v1.xA0
AT Command: ATIT
Parameter Range: 1 - 0xFF
Default Parameter Value:1
Minimum Firmware Version Required: v1.xA0
     41