Specifications of XBP24-PKI-001-RA

Frequency
2.4GHz
Data Rate - Maximum
250kbps
Modulation Or Protocol
802.15.4
Applications
Home/Building Automation, Industrial Control, ZigBee™
Power - Output
0dBm
Sensitivity
-92dBm
Voltage - Supply
2.8 V ~ 3.4 V
Current - Receiving
55mA
Data Interface
Connector, Female DB-9
Antenna Connector
RP-SMA
Operating Temperature
-40°C ~ 85°C
Package / Case
Module
Memory Size
-
Current - Transmitting
-
Other names
Q3255595
© 2008 Digi International, Inc. 
XBee‐PRO PKG‐R® RS‐232 RF Modem – 802.15.4 ‐ Product Manual v1.xAx 
NI (Node Identifier) Command
NT (Node Discover Time) Command
P0 (PWM0 Configuration) Command
P1 (PWM1 Configuration) Command
<Networking {Identification}> The NI command
is used to set and read a string for identifying a
particular node.
Rules:
This string is returned as part of the ND (Node Discover) command. This identifier is also used
with the DN (Destination Node) command.
<Networking {Identification}> The NT command
is used to set the amount of time a base node will
wait for responses from other nodes when using
the ND (Node Discover) command. The NT value
is transmitted with the ND command.
Remote nodes will set up a random hold-off time
based on this time. The remotes will adjust this
time down by 250 ms to give each node the
ability to respond before the base ends the command. Once the ND command has ended, any
response received on the base would be discarded.
<I/O Setting {I/O Line Passing}> The P0
command is used to select/read the function for
PWM0 (Pulse Width Modulation output 0). This
command enables the option of translating
incoming data to a PWM so that the output can be
translated back into analog form.
With the IA (I/O Input Address) parameter
correctly set, AD0 values can automatically be
passed to PWM0.
<I/O Setting {I/O Line Passing}> The P1
command is used to select/read the function for
PWM1 (Pulse Width Modulation output 1). This
command enables the option of translating
incoming data to a PWM so that the output can be
translated back into analog form.
With the IA (I/O Input Address) parameter
correctly set, AD1 values can automatically be
passed to PWM1.
• Register only accepts printable ASCII data.
• A string can not start with a space.
• A carriage return ends command
• Command will automatically end when maximum bytes for the string have been entered.
AT Command: ATNI
Parameter Range: 20-character ASCII string
Related Commands: ND (Node Discover), DN
(Destination Node)
Minimum Firmware Version Required: v1.x80
AT Command: ATNT
Parameter Range: 0x01 - 0xFC
Default: 0x19 (2.5 decimal seconds)
Related Commands: ND (Node Discover)
Minimum Firmware Version Required: 1.xA0
AT Command: ATP0
The second character in the command is the
number zero (“0”), not the letter “O”.
Parameter Range: 0 - 2
AT Command: ATP1
Parameter Range: 0 - 2
Default Parameter Value: 0
Minimum Firmware Version Required: v1.xA0
Default Parameter Value: 1
Parameter
Parameter
0
1
2
0
1
2
[x 100 msec]
Configuration
PWM1 Output
Configuration
PWM0 Output
Disabled
Disabled
RSSI
RSSI
     44