XBP24-PKI-001-RA Digi International/Maxstream, XBP24-PKI-001-RA Datasheet - Page 42

no-image

XBP24-PKI-001-RA

Manufacturer Part Number
XBP24-PKI-001-RA
Description
MODULE 802.15.4 RS-232 ANT
Manufacturer
Digi International/Maxstream
Series
XBEE-PRO™r

Specifications of XBP24-PKI-001-RA

Frequency
2.4GHz
Data Rate - Maximum
250kbps
Modulation Or Protocol
802.15.4
Applications
Home/Building Automation, Industrial Control, ZigBee™
Power - Output
0dBm
Sensitivity
-92dBm
Voltage - Supply
2.8 V ~ 3.4 V
Current - Receiving
55mA
Data Interface
Connector, Female DB-9
Antenna Connector
RP-SMA
Operating Temperature
-40°C ~ 85°C
Package / Case
Module
Memory Size
-
Current - Transmitting
-
Other names
Q3255595
© 2008 Digi International, Inc. 
XBee‐PRO PKG‐R® RS‐232 RF Modem – 802.15.4 ‐ Product Manual v1.xAx 
IU (I/O Output Enable) Command
KY (AES Encryption Key) Command
M0 (PWM0 Output Level) Command
M1 (PWM1 Output Level) Command
<I/O Settings> The IU command is used to
disable/enable I/O UART output. When enabled
(IU = 1), received I/O line data packets are sent
out the UART. The data is sent using an API frame
regardless of the current AP parameter value.
<Networking {Security}> The KY command is
used to set the 128-bit AES (Advanced Encryption
Standard) key for encrypting/decrypting data.
Once set, the key cannot be read out of the
module by any means.
The entire payload of the packet is encrypted
using the key and the CRC is computed across the
ciphertext. When encryption is enabled, each packet carries an additional 16 Bytes to convey the
random CBC Initialization Vector (IV) to the receiver(s). The KY value may be “0” or any 128-bit
value. Any other value, including entering ATKY by itself with no parameters, will cause an error. A
module with the wrong key (or no key) will receive encrypted data, but the data driven out the
serial port will be meaningless. Likewise, a module with a key will receive unencrypted data sent
from a module without a key, but the output will be meaningless. Because CBC mode is utilized,
repetitive data appears differently in different transmissions due to the randomly-generated IV.
When queried, the system will return an ‘OK’ message and the value of the key will not be
returned.
<I/O Settings> The M0 command is used to set/
read the output level of the PWM0 line (pin 6).
Before setting the line as an output:
The PWM period is 64 µsec and there are 0x03FF
(1023 decimal) steps within this period. When M0
= 0 (0% PWM), 0x01FF (50% PWM), 0x03FF
(100% PWM), etc.
<I/O Settings> The M1 command is used to set/
read the output level of the PWM1 line (pin 7).
Before setting the line as an output:
1. Enable PWM0 output (P0 = 2)
2. Apply settings (use CN or AC)
1. Enable PWM1 output (P1 = 2)
2. Apply settings (use CN or AC)
AT Command: ATKY
Parameter Range:0 - (any 16-Byte value)
Default Parameter Value:0
Related Command: EE (Encryption Enable)
Minimum Firmware Version Required: v1.xA0
AT Command: ATM0
Parameter Range:0 - 0x03FF [steps]
Default Parameter Value:0
Related Commands: P0 (PWM0 Enable), AC
(Apply Changes), CN (Exit Command Mode)
Minimum Firmware Version Required: v1.xA0
AT Command: ATM1
Parameter Range:0 - 0x03FF
Default Parameter Value:0
Related Commands: P1 (PWM1 Enable), AC
(Apply Changes), CN (Exit Command Mode)
Minimum Firmware Version Required: v1.xA0
AT Command: ATIU
Parameter Range:0 - 1
Default Parameter Value:1
Minimum Firmware Version Required: 1.xA0
Parameter
0
1
Received I/O line data
Received I/O line data
packets will NOT sent
will be sent out UART
Configuration
Disabled -
out UART.
Enabled -
     42