ATTINY261-20MUR Atmel, ATTINY261-20MUR Datasheet - Page 26

IC MCU AVR 2K FLASH 20MHZ 32QFN

ATTINY261-20MUR

Manufacturer Part Number
ATTINY261-20MUR
Description
IC MCU AVR 2K FLASH 20MHZ 32QFN
Manufacturer
Atmel
Series
AVR® ATtinyr
Datasheets

Specifications of ATTINY261-20MUR

Core Processor
AVR
Core Size
8-Bit
Speed
20MHz
Connectivity
USI
Peripherals
Brown-out Detect/Reset, POR, PWM, WDT
Number Of I /o
16
Program Memory Size
2KB (1K x 16)
Program Memory Type
FLASH
Eeprom Size
128 x 8
Ram Size
128 x 8
Voltage - Supply (vcc/vdd)
2.7 V ~ 5.5 V
Data Converters
A/D 11x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
32-VFQFN Exposed Pad
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
6.2.1
6.2.2
26
ATtiny261/461/861
External Clock
High-Frequency PLL Clock
mencing normal operation. The watchdog oscillator is used for timing this real-time part of the
start-up time. The number of WD oscillator cycles used for each time-out is shown in
Table 6-2.
To drive the device from an external clock source, CLKI should be driven as shown in
2. To run the device on an external clock, the CKSEL Fuses must be programmed to “0000”.
Figure 6-2.
When this clock source is selected, start-up times are determined by the SUT Fuses as shown in
Table
Table 6-3.
When applying an external clock, it is required to avoid sudden changes in the applied clock fre-
quency to ensure stable operation of the MCU. A variation in frequency of more than 2% from
one clock cycle to the next can lead to unpredictable behavior. It is required to ensure that the
MCU is kept in Reset during such changes in the clock frequency.
Note that the system clock prescaler can be used to implement run-time changes of the internal
clock frequency. See
The internal PLL generates a clock signal with a frequency eight times higher than the source
input. The PLL uses the output of the internal 8 MHz oscillator as source and the default setting
generates a fast peripheral clock signal of 64 MHz.
SUT1:0
00
01
10
11
6-3.
Typ Time-out
Start-up Time from Power-
Number of Watchdog Oscillator Cycles
External Clock Drive Configuration
Start-up Times for the External Clock Selection
EXTERNAL
down and Power-save
64 ms
4 ms
SIGNAL
CLOCK
“System Clock Prescaler” on page 31
6 CK
6 CK
6 CK
Additional Delay from
Reserved
14CK + 64 ms
14CK + 4 ms
Reset
14CK
CLKI
GND
for details.
Number of Cycles
8K (8,192)
512
BOD enabled
Fast rising power
Slowly rising power
Recommended Usage
2588E–AVR–08/10
Table
Figure 6-
6-2.

Related parts for ATTINY261-20MUR