CV500BC051 Omron, CV500BC051 Datasheet - Page 375

no-image

CV500BC051

Manufacturer Part Number
CV500BC051
Description
Programmable Logic Controller
Manufacturer
Omron
Datasheet

Specifications of CV500BC051

Peak Reflow Compatible (260 C)
No
Leaded Process Compatible
No
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Parameters for Automatically Setting Data Links with Equality Layout: D30000 + 100 × (Unit
No.) + 1 to 9 (See page 147.)
Parameters for Automatic Data Link Creation with 1:N Allocation: D30000 + 100 × (Unit No.) +
12 to 25
Common Type
Words N+22 through N+25 register nodes that will participate in the data links. The numbers shown in the table
are the node addresses. The bit status for each node address indicates whether the node is to participate in
the data links.
350
Memory Areas
N+12
N+13
N+14
N+15
N+16
N+17
N+18
N+19
N+20
N+21
N+22
N+23
N+24
N+25
+8
+9
+10
+11
+1
+2
+3
+4
+5
+6
+7
Participate: ON
Not participate: OFF
Area 1 data link start word (BCD)
Area 1 type
Number of send words per node of area 1 (BCD)
Rightmost 4 digits of data link start word of area 2 (DM area) (BCD)
Area 2 type
Number of send words per node of area 2 (BCD)
First data link status word (BCD)
15
15 14 13 12 11 10 9
16 15 14 13 12 11 10 9
32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17
48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33
BCD: Set the value as binary-coded decimal.
15
16
32
48
---
− 62 61 60 59 58 57 56 55 54 53 52 51 50 49
15
31
47
---
14
30
46
62
Area for area 1
Area for area 2
13
29
45
61
8
1:N allocation type (Set value 0001 = Common type)
8
Rightmost 4 digits of start word of area 2 (DM area) (BCD)
Area 1 send size (number of words) for master node (BCD)
Area 2 send size (number of words) for master node (BCD)
12
28
44
60
7
8
Area 1 send size (number of words) for slave nodes (BCD)
Area 2 send size (number of words) for slave nodes (BCD)
Leftmost digit of data link start word of area
2 (BCD)
00
7
6
7
First word to store data link status (bit-access area) (BCD)
11
27
43
59
Start word for area 1 (bit-access area, BCD)
5
6
4
5
10
26
42
58
3
4
25
41
57
2
3
8
9
1
2
24
40
56
7
8
0
1
0
Leftmost digit of start word of area 2 (BCD)
23
39
55
7
Nodes to participate in the data links
The numbers indicate node numbers.
The value assigned indicates whether the
node is to participate in the data links.
Participate:
Not participate: 0
22
38
54
6
21
37
53
5
00
1
20
36
52
4
19
35
51
3
18
34
50
2
Appendix B
17
33
49
0
1