Making the Cable to Connect to the PC
Making the Cable
The procedure to make up the cable is described below.
Cable Preparation
The preparation of the cable differs according to whether or not the shield is to be connected to the FG.
S Cable with Shield Connected to FG
S Cable with Shield Not Connected to FG
(1) Cut the cable to the required length.
(2) Remove the external vinyl insulation from the cable with a razor blade. Take care not to damage the shield-
(3) Cut back the shield with scissors.
(4) Use wire strippers to strip the insulation from each wire.
(5) Fold back the shield.
(6) Wrap aluminum foil tape around the folded-back shield.
(1) Cut the cable to the required length.
(2) Remove the external vinyl insulation from the cable with a razor blade. Take care not to damage the shield
- RS-422A type NT30/30C
ing underneath.
underneath.
RS-422A
Terminal
block
NT30/30C
Abbrev.
RDA
RDB
SDA
SDB
RS-422A
Shield
(1)
(2)
(3)
(4)
(5)
(6)
Pin No.
1
2
3
4
5
6
7
8
Terminal block
5(0.19)
Abbrev.
SDB
SDA
RDB
RDA
CSB
CSA
40 (1.57) (RS-232C)
FG
SG
25 (1.00) (RS-422)
RS-422A
interface
NT-AL001
RS-232C
interface
10(0.39)
Aluminum foil tape
(9-pin)
Abbrev.
DSR
+5V
FG
SG
RD
RS
CS
ER
SG
Terminal
No.
1
2
3
4
5
6
7
8
9
RS-232C
Shield
Abbrev.
DSR
RD
SG
FG
SD
RS
CS
ER
Host
[Units: mm (in.)]
RS-232C
interface
Appendix E
279