S CS1-series CPU Unit: CS1H/G-CPUjj(-V1)
Connect to the CPU Unit’s RS-232C port or the RS-232C port of the Communica-
tions Board. When connecting to the peripheral port, use the CS1W-CN118 Con-
necting Cable.
DIP Switch Setting for CPM2C
With the CPM2C, in order that the PC Setup settings (data memory) are
enabled, set the DIP switches on the front panel in the way described below.
If (1) the PT is connected to the peripheral port or (2) the PT is connected to the
RS-232C port and a device that requires communications settings other than
the standard settings is connected to the peripheral port, set the DIP switches in
the way shown below.
Switch Setting for the RS-232C Adapter
When using the CPM1-CIF01 RS-232C Adapter, set the mode setting switch in
the way shown below.
PC Setup Settings
When connecting to a CS1-series CPU Unit, make the PC Setup settings in the
following way. The settings are default settings for the PC Setup and so if the
baud rate is 9,600 bps, there is no need to make any changes to the default set-
tings.
S Set the mode setting switch to
Baud rate
Stop bit
Parity
Data length
Unit #
host (upper position).
Set the DIP switches according to the way the peripheral
port and the RS-232C port are used.
• If (1) the PT is connected to the peripheral port or (2) the PT is connected to
• If the PT is connected to the RS-232C port and a Programming Console is
the RS-232C port and a device that requires communications settings other
than the standard settings is connected to the peripheral port, set the DIP
switches in the way shown below.
connected to the peripheral port, set the DIP switches in the way shown
below.
Item
Set to the same baud rate as the NT30/NT30C (See note 1.)
2 stop bits
Even
ASCII 7 bits
00
Set SW1 to OFF.
Set SW2 to ON.
CPM1
-CIF01
Contents of Settings at Host
Set SW1 to OFF.
Set SW2 to OFF.