0
Frame control
Horizontal mirror and vertical flip
Video pipe setup
Context switching
20/106
The image data output from the VL6624/VS6624 can be mirrored horizontally or flipped
vertically (or both).
The VS6624 has a single video pipe, the control of this pipe can be loaded from either of two
possible setups Pipesetupbank0 and Pipesetupbank1;
Pipe setup bank0
Pipe 0 RGB to YUV matrix manual control
allow different RGB to YUV matrixes to be used for each pipe setup,
Pipe 0 gamma manual control
settings to be used for each pipe setup.
In normal operation, it is possible to control which pipe setup bank is used and to switch
between banks without the need to stop streaming, the change will occur at the next frame
boundary after the change to the register has been made.
For example this function allows the VL6624/VS6624 to stream an output targeting a display
(e.g. QQVGA RGB 444) then switch to capture an image (e.g. SXGA YUV 4:2:2) with no
need to stop streaming or enter any other operating mode.
It is important to note the output size selected for both pipe setups must be appropriate to
the sensor mode used, i.e. to configure PipeSetupBank0 to QQVGA and PipeSetupBank1
to SXGA the sensor mode must be set to SXGA.
The register
bank 0 is used.
image size
zoom control
pan control
Crop control
Image format (YUV 4:2:2, RGB565, etc....)
Image controls (Contrast, Color saturation, Horizontal and vertical flip)
Mode setup
and
Pipe setup bank1
allows selection of the pipe setup bank, by default the Pipe setup
and
Pipe 1 Gamma manual control
, control the operations shown below,
and
Pipe 1 RGB to YUV matrix manual control
, allow different gamma
VL6624/VS6624
,