VS6624Q0KP STMicroelectronics, VS6624Q0KP Datasheet - Page 41

no-image

VS6624Q0KP

Manufacturer Part Number
VS6624Q0KP
Description
Display Modules & Development Tools CAMERA MODULE SINGLE CHIP 1.3MEGA
Manufacturer
STMicroelectronics
Datasheet

Specifications of VS6624Q0KP

Description/function
Camera Module
Interface Type
Two-Wire Serial
Data Bus Width
8 bit
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
VS6624Q0KP/TR
Manufacturer:
ST
0
VL6624/VS6624
10.8
Figure 26. Random location, single write
10.9
Figure 27. Current location, single read
16-bit index, 8-bit data current location, single data read
‘1’ (Read)
S
16-bit Index, 8-bit Data, Random Location, Single Data Write
S
From Master to Slave
DEV ADDR R/W A
From Slave to Master
‘0’ (Write)
DEV ADDR R/W A
From Slave to Master
From Master to Slave
Random location, single data write
For the master writing to the slave the R/W bit is set to zero.
The register index value written is preserved and is used by a subsequent read. The write
message is terminated with a stop condition from the master.
Current location, single data read
For the master reading from the slave the R/W bit is set to one. The register index of the
data returned is that accessed by the previous read or write message.
The first data byte returned by a read message is the contents of the internal index value
and NOT the index value. This was the case in older V2W implementations.
Note that the read message is terminated with a negative acknowledge (A) from the master:
it is not guaranteed that the master will be able to issue a stop condition at any other time
during a read message. This is because if the data sent by the slave is all zeros, the SDA
line cannot rise, which is part of the stop condition.
Previous Index Value, K
DATA[7:0]
DATA[7:0]
DATA
INDEX[15:8]
DATA
S = START Condition
Sr = repeated START
P = STOP Condition
S = START Condition
Sr = repeated START
P = STOP Condition
Index[15:0]
A
value, M
Previous Index Value, K
A
P
INDEX[7:0]
DATA
Host communication - I²C control interface
A
A = Acknowledge
A = Negative Acknowledge
A = Acknowledge
A = Negative Acknowledge
DATA[7:0]
DATA[7:0]
DATA
A/A
Index M
P
41/106