LAN9303I-ABZJ SMSC, LAN9303I-ABZJ Datasheet - Page 134

no-image

LAN9303I-ABZJ

Manufacturer Part Number
LAN9303I-ABZJ
Description
Ethernet ICs 3 Port 0/100 Ether Switch MII/RMII/Turb
Manufacturer
SMSC
Datasheet

Specifications of LAN9303I-ABZJ

Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LAN9303I-ABZJ
Manufacturer:
Standard
Quantity:
1 955
Part Number:
LAN9303I-ABZJ
Manufacturer:
SMSC10
Quantity:
510
Part Number:
LAN9303I-ABZJ
Manufacturer:
SMSC
Quantity:
20 000
Revision 1.4 (07-07-10)
12.3.1
LED Function Definitions when LED_FUN[1:0] = 00b, 01b, or 10b
When
When
apply:
“Active” is defined as the pin being driven to the opposite value latched at reset on the
led_pol_strap[5:0]
detailed in
via soft-straps.
“Inactive” is defined as the pin not being driven.
The input buffers and pull-ups are disabled on the shared GPIO/LED pins.
TX Port 0 - The signal is pulsed active for 80mS to indicate activity from the Switch Fabric to the
external MII pins. This signal is then made inactive for a minimum of 80mS, after which the process
will repeat if TX activity is again detected.
Note: Link indication does not affect this function.
RX Port 0 - The signal is pulsed active for 80mS to indicate activity from the external MII pins to
the Switch Fabric. This signal is then made inactive for a minimum of 80mS, after which the
process will repeat if RX activity is again detected.
Note: Link indication does not affect this function.
Link / Activity Port 1/2 - A steady active output indicates that the port has a valid link, while a
steady inactive output indicates no link on the port. The signal is pulsed inactive for 80mS to
indicate transmit or receive activity on the port. The signal is then made active for a minimum of
80mS, after which the process will repeat if RX or TX activity is again detected.
Full-duplex / Collision Port 1/2 - A steady active output indicates the port is in full-duplex mode.
In half-duplex mode, the signal is pulsed active for 80mS to indicate a network collision. The signal
is then made inactive for a minimum of 80mS, after which the process will repeat if another collision
is detected. The signal will be held inactive if the port does not have a valid link.
Speed Port 1/2 - A steady active output indicates a valid link with a speed of 100Mbps. A steady
inactive output indicates a speed of 10Mbps. The signal will be held inactive if the port does not
have a valid link.
100Link / Activity Port 1/2 - A steady active output indicates the port has a valid link and the
speed is 100Mbps. The signal is pulsed inactive for 80mS to indicate TX or RX activity on the port.
The signal is then driven active for a minimum of 80mS, after which the process will repeat if RX
or TX activity is again detected. The signal will be held inactive if the port does not have a valid
link or the speed is not 100Mbps.
10Link / Activity Port 1/2 - A steady active output indicates the port has a valid link and the speed
is 10Mbps. The signal is pulsed inactive for 80mS to indicate transmit or receive activity on the
port. The signal is then driven active for a minimum of 80mS, after which the process will repeat if
RX or TX activity is again detected. This signal will be held inactive if the port does not have a
valid link or the speed is not 10Mbps.
LED Function 1-0 (LED_FUN[1:0])
LED Function 1-0 (LED_FUN[1:0])
Section 4.2.4, "Configuration Straps," on page
LED polarity hard-straps. LED polarity is determined by these hard-straps as
Small Form Factor Three Port 10/100 Managed Ethernet Switch with Single MII/RMII/Turbo MII
DATASHEET
is 00b, 01b, or 10b, the following LED rules apply:
134
is 00b, 01b, or 10b, the following LED function definitions
45. The LED polarity cannot be modified
SMSC LAN9303/LAN9303i
Datasheet

Related parts for LAN9303I-ABZJ