6.4.2.1
F1 Index 10h, Base Address Register 0 (F1BAR0), points
to the base address for SMI Status register locations. Table
6-33 gives the bit formats of I/O mapped SMI Status regis-
ters accessed through F1BAR0.
246
Offset 00h-01h
Note:
Bit
15
14
13
12
11
10
9
8
7
6
Reading this register does not clear the status bits. For more information, see F1BAR0+I/O Offset 02h.
SMI Status Support Registers
Description
Suspend Modulation Enable Mirror. This bit mirrors the Suspend Mode Configuration bit (F0 Index 96h[0]). It is used by
the SMI handler to determine if the SMI Speedup Disable Register (F1BAR0+I/O Offset 08h) must be cleared on exit.
SMI Source is USB. Indicates whether or not an SMI was caused by USB activity.
0: No.
1: Yes.
To enable SMI generation, set F5BAR0+I/O Offset 00h[20:19] to 11.
SMI Source is Warm Reset Command. Indicates whether or not an SMI was caused by a Warm Reset command.
0: No.
1: Yes.
SMI Source is NMI. Indicates whether or not an SMI was caused by NMI activity.
0: No.
1: Yes.
SMI Source is IRQ2 of SIO Module. Indicates whether or not an SMI was caused by IRQ2 of the SIO module.
0: No.
1: Yes.
The next level (second level) of SMI status is reported in the SuperI/O module. For more information, see Table 5-29 "Banks
0 and 1 - Common Control and Status Registers" on page 125, Offset 00h.
SMI Source is EXT_SMI[7:0]. Indicates whether or not an SMI was caused by a negative-edge event on EXT_SMI[7:0].
0: No.
1: Yes.
The next level (second level) of SMI status is at F1BAR0+I/O Offset 24h[23:8].
SMI Source is GP Timers/UDEF/PCI/ISA Function Trap. Indicates if an SMI was caused by:
0: No.
1: Yes.
The next level (second level) of SMI status is at F1BAR0+I/O Offset 04h/06h.
SMI Source is Software Generated. Indicates whether or not an SMI was caused by software.
0: No.
1: Yes.
SMI on an A20M# Toggle. Indicates whether or not an SMI was caused by a write access to either Port 92h or the key-
board command which initiates an A20M# SMI.
0: No.
1: Yes.
This method of controlling the internal A20M# in the GX1 module is used instead of a pin.
To enable SMI generation, set F0 Index 53h[0] to 1.
SMI Source is a VGA Timer Event. Indicates whether or not an SMI was caused by the expiration of the VGA Timer (F0
Index 8Eh).
0: No.
1: Yes.
To enable SMI generation, set F0 Index 83h[3] to 1.
— Expiration of GP Timer 1 or 2.
— Trapped access to UDEF1, 2, or 3.
— Trapped access to F1-F5 or ISA Legacy register space.
32580B
Table 6-33. F1BAR0+I/O Offset: SMI Status Registers
Top Level PME/SMI Status Mirror Register (RO)
Core Logic Module - SMI Status and ACPI Registers - Function 1
The registers at F1BAR0+I/O Offset 50h-FFh can also be
accessed F0 Index 50h-FFh. The preferred method is to
program these registers through the F0 register space.
AMD Geode™ SC2200 Processor Data Book
Reset Value: 0000h