S19252PBIDB Applied Micro Circuits Corporation, S19252PBIDB Datasheet - Page 59

no-image

S19252PBIDB

Manufacturer Part Number
S19252PBIDB
Description
Manufacturer
Applied Micro Circuits Corporation
Datasheet

Specifications of S19252PBIDB

Lead Free Status / Rohs Status
Supplier Unconfirmed
Performance Specifications
Table 28: Performance Specifications
Revision 5.03
Nominal VCO Center Frequency (CSU
and CRU)
TX and RX VCO frequency
([T/R]X_VCO_Range = 00)
TX and RX VCO frequency
([T/R]X_VCO_Range = 01)
TX and RX VCO frequency
([T/R]X_VCO_Range = 10)
TX and RX VCO frequency
([T/R]X_VCO_Range = 11)
Frequency difference at which the receive
PLL goes out of lock (CRU_REFCLK
compared to the divided down VCO
clock). LOCKDET is de-asserted when
PLL goes out of lock.
Frequency difference at which receive
PLL goes into lock (CRU_REFCLK com-
pared to the divided down VCO clock).
LOCKDET is asserted 0.5 ms after PLL
goes into lock.
CRU Acquisition phase lock time
SONET J
(SERDATIP/N) 
with PAEQUADJ[2:0] = 0,0,0
tol
Jitter Tolerance 
Parameter
AppliedMicro - Confidential and Proprietary
CSU and CRU VCO Specifications
See Figure
SONET Jitter Specifications
10.30
10.51
± 350
± 220
11.00
9.95
9.95
Min
8
Typ
10.00
10.32
10.71
± 600
± 530
11.32
11.32
Max
500
UI
UI
UI
UI
UI
Units
GHz
GHz
GHz
GHz
GHz
ppm
ppm
us
(p-p)
(p-p)
(p-p)
(p-p)
(p-p)
Refer to Application Note
AN2019 for Data Rate Selec-
tion Register Control Settings
VCO frequency guaranteed
with + 600 ppm offset
LOCKDET “into lock” status is
only valid when the incoming
data is within +800 ppm of the
VCO clock.
Note the VCO clock is a multiple of the
CRU_REFCLK when out of lock.
After the release of RSTB,
with device already powered
up and with a valid
CRU_REFCLK. Guaranteed
but not tested.
10 Hz – 2.4 kHz
(Sinusoidal)
2.4 kHz – 24 kHz
(Sinusoidal)
24 kHz – 400 kHz
(Sinusoidal)
400 kHz – 4 MHz
(Sinusoidal)
4 MHz–80 MHz (Sinusoidal)
SONET spec of 0.15 UI is met
across the entire range of
9.95 to 10.709 GHz
Conditions
S19252 Data Sheet