SI3018-F-FSR Silicon Laboratories Inc, SI3018-F-FSR Datasheet - Page 74

Modem Chip Chipset 16-Pin SOIC T/R

SI3018-F-FSR

Manufacturer Part Number
SI3018-F-FSR
Description
Modem Chip Chipset 16-Pin SOIC T/R
Manufacturer
Silicon Laboratories Inc
Datasheet

Specifications of SI3018-F-FSR

Package
16SOIC
Main Category
Chipset
Sub-category
Data/Voice
Typical Operating Supply Voltage
3.3 V
Power Supply Type
Digital
Typical Supply Current
8.5 mA
Minimum Operating Supply Voltage
3 V
Maximum Operating Supply Voltage
3.6 V
Data Rate
54.6875Kbps
Operating Supply Voltage (typ)
3.3V
Operating Supply Voltage (min)
3V
Operating Supply Voltage (max)
3.6V
Operating Temp Range
0C to 70C
Operating Temperature Classification
Commercial
Pin Count
16
Mounting
Surface Mount
Lead Free Status / Rohs Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SI3018-F-FSR
Manufacturer:
SiliconL
Quantity:
52 026
Part Number:
SI3018-F-FSR
Manufacturer:
SILICON
Quantity:
57
Part Number:
SI3018-F-FSR
Manufacturer:
SILICOM
Quantity:
10 000
Part Number:
SI3018-F-FSR
Manufacturer:
SILICONLABS/芯科
Quantity:
20 000
Company:
Part Number:
SI3018-F-FSR
Quantity:
2 488
Si3050 + Si3018/19
Register 19. International Control 4
Reset settings = 0000_0000
74
Bit
7:3
2
1
0
Name
Type
Bit
Reserved
Name
DOD
OPD
OVL
D7
Receive Overload Detect.
This bit has the same function as ROV (Register 17), but clears itself after the overload is
removed. See “5.22.Receive Overload Detection” on page 33. This bit is only masked by the
off-hook counter and is not affected by the BTE bit.
0 = Normal receive input level.
1 = Excessive receive input level.
Recal/Dropout Detect.
When the line-side device is off-hook, it is powered from the line itself. This bit will read 1
when loop current is not flowing. For example, if this line-derived power supply collapses,
such as when the line is disconnected, this bit is set to 1. Additionally, when on-hook, and the
line-side device is enabled, this bit is set to 1.
0 = Normal operation.
1 = Line supply dropout detected when off-hook.
Overload Protect Detect.
This bit is used to indicate that the DAA has detected a loop current overload. The detector fir-
ing threshold depends on the setting of the ILIM bit (Register 26).
OPD
Read returns zero.
0
0
1
1
ILIM
D6
0
1
0
1
Overcurrent Threshold
D5
160 mA
60 mA
160 mA
60 mA
Rev. 1.31
D4
Function
D3
Overcurrent Status
Overcurrent condition has been detected
Overcurrent condition has been detected
No overcurrent condition exists
No overcurrent condition exists
OVL
D2
R
DOD
D1
R
OPD
D0
R

Related parts for SI3018-F-FSR