EP4CGX15BF14C8N Altera, EP4CGX15BF14C8N Datasheet - Page 100

IC CYCLONE IV FPGA 15K 169FBGA

EP4CGX15BF14C8N

Manufacturer Part Number
EP4CGX15BF14C8N
Description
IC CYCLONE IV FPGA 15K 169FBGA
Manufacturer
Altera
Series
CYCLONE® IV GXr

Specifications of EP4CGX15BF14C8N

Number Of Logic Elements/cells
14400
Number Of Labs/clbs
900
Total Ram Bits
540000
Number Of I /o
72
Voltage - Supply
1.16 V ~ 1.24 V
Mounting Type
Surface Mount
Operating Temperature
0°C ~ 85°C
Package / Case
169-FBGA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Number Of Gates
-
Other names
544-1475

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EP4CGX15BF14C8N
Manufacturer:
ALTERA33
Quantity:
276
Part Number:
EP4CGX15BF14C8N
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP4CGX15BF14C8N
Manufacturer:
ALTERA
0
Part Number:
EP4CGX15BF14C8N
0
5–38
Cyclone IV Device Handbook, Volume 1
The rselodd bit indicates an odd divide factor for the VCO output frequency with a
50% duty cycle. For example, if the post-scale divide factor is three, the high and low
time count values are 2 and 1, respectively, to achieve this division. This implies a
67%–33% duty cycle. If you need a 50%–50% duty cycle, you must set the rselodd
control bit to 1 to achieve this duty cycle despite an odd division factor. The PLL
implements this duty cycle by transitioning the output clock from high-to-low on a
falling edge of the VCO output clock. When you set rselodd = 1, subtract 0.5 cycles
from the high time and add 0.5 cycles to the low time.
For example:
Scan Chain Description
Cyclone IV PLLs have a 144-bit scan chain.
Table 5–7
Table 5–7. Cyclone IV PLL Reprogramming Bits
C4
C3
C2
C1
C0
M
N
Charge Pump
Loop Filter
Total number of bits:
Notes to
(1) LSB bit for C4 low
(2) These two control bits include rbypass, for bypassing the counter, and rselodd, to select the output clock
(3) MSB bit for loop filter is the last bit shifted into the scan chain.
High time count = 2 cycles
Low time count = 1 cycle
rselodd = 1 effectively equals:
(1)
Block Name
duty cycle.
High time count = 1.5 cycles
Low time count = 1.5 cycles
Duty cycle = (1.5/3)% high time count and (1.5/3)% low time count
Table
lists the number of bits for each component of the PLL.
(3)
5–7:
-
count value is the first bit shifted into the scan chain.
Counter
16
16
16
16
16
16
16
9
9
Chapter 5: Clock Networks and PLLs in Cyclone IV Devices
Number of Bits
Other
2
2
2
2
2
2
2
(2)
(2)
(2)
(2)
(2)
(2)
(2)
0
0
© December 2010 Altera Corporation
PLL Reconfiguration
Total
144
18
18
18
18
18
18
18
9
9

Related parts for EP4CGX15BF14C8N