ADE7166ASTZF8 Analog Devices Inc, ADE7166ASTZF8 Datasheet - Page 58

IC ENERGY METER 1PHASE 64LQFP

ADE7166ASTZF8

Manufacturer Part Number
ADE7166ASTZF8
Description
IC ENERGY METER 1PHASE 64LQFP
Manufacturer
Analog Devices Inc
Datasheets

Specifications of ADE7166ASTZF8

Applications
Energy Measurement
Core Processor
8052
Program Memory Type
FLASH (8 kB)
Controller Series
ADE71xx
Ram Size
512 x 8
Interface
I²C, SPI, UART
Number Of I /o
20
Voltage - Supply
3.135 V ~ 3.465 V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
64-LQFP
Ic Function
Single Phase Energy Measurement IC
Supply Voltage Range
3.13V To 3.46V, 2.4V To 3.7V
Operating Temperature Range
-40°C To +85°C
Digital Ic Case Style
LQFP
No. Of Pins
64
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ADE7166ASTZF8
Manufacturer:
Analog Devices Inc
Quantity:
10 000
Part Number:
ADE7166ASTZF8-RL
Manufacturer:
Analog Devices Inc
Quantity:
10 000
ADE7566/ADE7569/ADE7166/ADE7169
Voltage Channel RMS Calculation
Figure 62 shows details of the signal processing chain for the
rms calculation on the voltage channel. The voltage channel
rms value is processed from the samples used in the voltage
channel waveform sampling mode and is stored in the unsigned
24-bit V
The update rate of the voltage channel rms measurement is
MCLK/5. To minimize noise in the reading of the register, the
V
crossing of the voltage input. This configuration is done by
setting the ZXRMS bit in the MODE2 register (0x0C).
With the specified full-scale ac analog input signal of 0.4 V, the
output from the LPF1 in Figure 62 swings between 0x28F5 and
0xD70B at 60 Hz (see the Voltage Channel ADC section). The
equivalent rms value of this full-scale ac signal is approximately
0d1,898,124 (0x1CF68C) in the V
measurement provided in the ADE7566/ADE7569/ADE7166/
ADE7169 is accurate to within ±0.5% for signal input between
full scale and full scale/20. The conversion from the register
value to volts must be done externally in the microprocessor
using a V/LSB constant.
Voltage Channel RMS Offset Compensation
The ADE7566/ADE7569/ADE7166/ADE7169 incorporate a
voltage channel rms offset compensation register (VRMSOS).
This is a 12-bit signed register that can be used to remove offset
in the voltage channel rms calculation. An offset can exist in the
rms calculation due to input noises and dc offset in the input
samples. One LSB of the voltage channel rms offset is equivalent
to 64 LSBs of the rms register. Assuming that the maximum
value from the voltage channel rms calculation is 0d1,898,124
with full-scale ac inputs, then 1 LSB of the voltage channel rms
offset represents 3.37% of measurement error at −60 dB down
of full scale.
where V
ACTIVE POWER CALCULATION
Active power is defined as the rate of energy flow from source
to load. It is the product of the voltage and current waveforms.
The resulting waveform is called the instantaneous power signal
and is equal to the rate of energy flow at every instant of time.
The unit of power is the watt or joules/second. Equation 10 gives an
expression for the instantaneous power signal in an ac system.
where:
v is the rms voltage.
i is the rms current.
rms
register can also be configured to update only with the zero
V
v
t i
p
p
( )
rms
( )
) (
) (
t
t
t
rms0
rms
= V
=
=
=
=
register.
is the rms measurement without offset correction.
VI
v
2
rms0
2
) (
t
×
×
VI
+ 64 × VRMSOS
I
×
V
sin(
t i
cos(
) (
sin(
ω
2
ω
t
ω
)
t
)
t
)
rms
register. The voltage rms
Rev. A | Page 58 of 144
(10)
(7)
(8)
(9)
The average power over an integral number of line cycles (n) is
given by the expression in Equation 11.
where:
T is the line cycle period.
P is referred to as the active or real power.
Note that the active power is equal to the dc component of the
instantaneous power signal p(t) in Equation 11, that is, VI. This
is the relationship used to calculate active power in the ADE7566/
ADE7569/ADE7166/ADE7169. The instantaneous power signal
p(t) is generated by multiplying the current and voltage signals. The
dc component of the instantaneous power signal is then extracted
by LPF2 (low-pass filter) to obtain the active power information.
This process is illustrated in
Because LPF2 does not have an ideal brick wall frequency
response (see Figure 64
ripple due to the instantaneous power signal. This ripple is
sinusoidal and has a frequency equal to twice the line frequency.
Because of its sinusoidal nature, the ripple is removed when the
active power signal is integrated to calculate energy (see the
Active Energy Calculation section).
0xCCCCD
0x19999A
0x00000
P
–12
–16
–20
–24
–4
–8
VI
=
0
1
nT
1
INSTANTANEOUS
POWER SIGNAL
CURRENT
i(t) = √2 × i × sin(ωt)
0
nT
Figure 64. Frequency Response of LPF2
p
Figure 63. Active Power Calculation
) (
VOLTAGE
v(t) = √2 × v × sin(ωt)
t
dt
3
), the active power signal has some
=
VI
FREQUENCY (Hz)
Figure 63.
p(t) = v × i – v × i × cos(2ωt)
10
ACTIVE REAL POWER
SIGNAL = v × i
30
1
00
(11)

Related parts for ADE7166ASTZF8