CY7C66113-PVC Cypress Semiconductor Corp, CY7C66113-PVC Datasheet - Page 37

IC MCU 8K USB HUB 4 PORT 56TSSOP

CY7C66113-PVC

Manufacturer Part Number
CY7C66113-PVC
Description
IC MCU 8K USB HUB 4 PORT 56TSSOP
Manufacturer
Cypress Semiconductor Corp
Datasheets

Specifications of CY7C66113-PVC

Applications
USB Hub/Microcontroller
Core Processor
M8
Program Memory Type
OTP (8 kB)
Controller Series
USB Hub
Ram Size
256 x 8
Interface
I²C, USB, HAPI
Number Of I /o
31
Voltage - Supply
4 V ~ 5.5 V
Operating Temperature
0°C ~ 70°C
Mounting Type
Surface Mount
Package / Case
56-SSOP
Operating Temperature (max)
70C
Operating Temperature (min)
0C
Operating Temperature Classification
Commercial
Mounting
Surface Mount
Pin Count
56
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
For Use With
CY3649 - PROGRAMMER HI-LO USB M8428-1339 - KIT LOW SPEED PERSONALITY BOARD
Lead Free Status / RoHS Status
Not Compliant, Contains lead / RoHS non-compliant
Other names
428-1330

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
CY7C66113-PVC
Manufacturer:
CY
Quantity:
10
Bit [0..6] : Port x SE0 Status (where x = 1..7)
Bit 7 : Reserved.
Hub Ports Data
Bit [0..6] : Port x Diff Data (where x = 1..7)
Bit 7 : Reserved.
18.4
The Hub Ports Suspend Register (Figure 18-9) and Hub Ports Resume Status Register (Figure 18-10) indicate the suspend and
resume conditions on downstream ports. The suspend register must be set by firmware for any ports that are selectively
suspended. Also, this register is only valid for ports that are selectively suspended.
If a port is marked as selectively suspended, normal USB traffic is not sent to that port. Resume traffic is also prevented from
going to that port, unless the Resume comes from the selectively suspended port. If a resume condition is detected on the port,
hardware reflects a Resume back to the port, sets the Resume bit in the Hub Ports Resume Register, and generates a hub
interrupt.
If a disconnect occurs on a port marked as selectively suspended, the suspend bit is cleared.
The Device Remote Wakeup bit (bit 7) of the Hub Ports Suspend Register controls whether or not the resume signal is propagated
by the hub after a connect or a disconnect event. If the Device Remote Wakeup bit is set, the hub will automatically propagate
the resume signal after a connect or a disconnect event. If the Device Remote Wakeup bit is cleared, the hub will not propagate
the resume signal. The setting of the Device Remote Wakeup flag has no impact on the propagation of the resume signal after
a downstream remote wakeup event. The hub will automatically propagate the resume signal after a remote wakeup event,
regardless of the state of the Device Remote wakeup bit. The state of this bit has no impact on the generation of the hub interrupt.
These registers are cleared on reset or bus reset.
These registers are cleared on reset or USB bus reset.
Hub Ports Suspend
Bit [0..6] : Port x Selective Suspend (where x = 1..7)
Bit 7 : Device Remote Wakeup.
Hub Ports Resume
Document #: 38-08024 Rev. *A
Bit #
Bit Name
Read/Write
Reset
Bit #
Bit Name
Read/Write
Reset
Bit #
Bit Name
Read/Write
Reset
Set to 1 if a SE0 is output on the Port x bus; Set to 0 if a Non-SE0 is output on the Port x bus.
Set to 0.
Set to 1 if D+ > D– (forced differential 1, if signal is differential, i.e. not a SE0 or SE1). Set to 0 if D– > D+ (forced differential
0, if signal is differential, i.e., not a SE0 or SE1);
Set to 0.
Set to 1 if Port x is Selectively Suspended; Set to 0 if Port x Do not suspend.
When set to 1, Enable hardware upstream resume signaling for connect/disconnect events during global resume.
When set to 0, Disable hardware upstream resume signaling for connect/disconnect events during global resume.
Downstream Port Suspend and Resume
7
Reserved
R
0
7
Device Remote
Wakeup
R/W
0
7
Reserved
-
0
6
Port 7
Selective
Suspend
R/W
0
6
Resume 7
R
0
6
Port 7 Diff. Data Port 6 Diff. Data Port 5 Diff. Data Port 4 Diff. Data Port 3 Diff. Data Port 2 Diff. Data Port 1 Diff. Data
R
0
5
Port 6
Selective
Suspend
R/W
0
5
Resume 6
R
0
5
R
0
Figure 18-10. Hub Ports Resume Status Register
Figure 18-9. Hub Ports Suspend Register
Figure 18-8. Hub Ports Data Register
4
Port 5
Selective
Suspend
R/W
0
4
Resume 5
R
0
4
R
0
3
Port 4
Selective
Suspend
R/W
0
3
Resume 4
R
0
3
R
0
2
Port 3
Selective
Suspend
R/W
0
2
R
0
Resume 3
2
R
0
1
Port 2
Selective
Suspend
R/W
0
1
Resume 2
R
0
1
R
0
CY7C66013
CY7C66113
ADDRESS 0x4E
ADDRESS 0x4D
ADDRESS 0x50
Page 37 of 58
0
Port 1
Selective
Suspend
R/W
0
0
Resume 1
R
0
0
R
0

Related parts for CY7C66113-PVC