ATtiny167 Atmel Corporation, ATtiny167 Datasheet - Page 51

no-image

ATtiny167

Manufacturer Part Number
ATtiny167
Description
Manufacturer
Atmel Corporation
Datasheets

Specifications of ATtiny167

Flash (kbytes)
16 Kbytes
Pin Count
20
Max. Operating Frequency
16 MHz
Cpu
8-bit AVR
# Of Touch Channels
8
Hardware Qtouch Acquisition
No
Max I/o Pins
16
Ext Interrupts
16
Usb Speed
No
Usb Interface
No
Spi
2
Twi (i2c)
1
Uart
1
Lin
1
Graphic Lcd
No
Video Decoder
No
Camera Interface
No
Adc Channels
11
Adc Resolution (bits)
10
Adc Speed (ksps)
15
Analog Comparators
1
Resistive Touch Screen
No
Temp. Sensor
Yes
Crypto Engine
No
Sram (kbytes)
0.5
Eeprom (bytes)
512
Self Program Memory
YES
Dram Memory
No
Nand Interface
No
Picopower
No
Temp. Range (deg C)
-40 to 85
I/o Supply Class
1.8 to 5.5
Operating Voltage (vcc)
1.8 to 5.5
Fpu
No
Mpu / Mmu
no / no
Timers
2
Output Compare Channels
3
Input Capture Channels
1
Pwm Channels
9
32khz Rtc
Yes
Calibrated Rc Oscillator
Yes

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ATtiny167-15MZ
Manufacturer:
ATMEL
Quantity:
670
Part Number:
ATtiny167-A15MZ
Manufacturer:
ATMEL
Quantity:
480
Part Number:
ATtiny167-A15MZ
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
Part Number:
ATtiny167-A15XD
Manufacturer:
BOSCH
Quantity:
40 000
Part Number:
ATtiny167-A15XZ
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
Part Number:
ATtiny167-AXZ
Quantity:
17
6.1.4
6.1.5
8265B–AVR–09/10
External Reset
Brown-out Detection
Figure 6-3.
An External Reset is generated by a low level on the RESET pin. Reset pulses longer than the
minimum pulse width (see
not running. Shorter pulses are not guaranteed to generate a reset. When the applied signal
reaches the Reset Threshold Voltage – V
the MCU after the Time-out period – t
by the RSTDISBL fuse, see
Figure 6-4.
ATtiny87/167 has an On-chip Brown-out Detection (BOD) circuit for monitoring the V
during operation by comparing it to a fixed trigger level. The trigger level for the BOD can be
selected by the BODLEVEL Fuses
level has a hysteresis to ensure spike free Brown-out Detection. The hysteresis on the detec-
tion level should be interpreted as V
When the BOD is enabled, and V
ure
level (V
has expired.
The BOD circuit will only detect a drop in V
ger than t
6-5), the Brown-out Reset is immediately activated. When V
INTERNAL
TIME-OUT
RESET
RESET
BOT
V
CC
BOD
CC
+
in
given in
MCU Start-up, RESET Extended Externally
External Reset During Operation
Figure
Table 22-6 on page
6-5), the delay counter starts the MCU after the Time-out period t
V
CCRR
Table 22-3 on page
Table 21-4 on page
V
CC
POR
(See ”BODLEVEL Fuse Coding” on page
BOT
decreases to a value below the trigger level (V
TOUT
+
= V
CC
247.
RST
– has expired. The External Reset can be disabled
BOT
if the voltage stays below the trigger level for lon-
– on its positive edge, the delay counter starts
246) will generate a reset, even if the clock is
+ V
226.
HYST
V
RST
/ 2 and V
t
TOUT
CC
BOT
increases above the trigger
= V
BOT
247.). The trigger
- V
HYST
BOT
/ 2.
CC
in
level
TOUT
Fig-
51

Related parts for ATtiny167