TMP86xy12MG Toshiba, TMP86xy12MG Datasheet - Page 104

no-image

TMP86xy12MG

Manufacturer Part Number
TMP86xy12MG
Description
Manufacturer
Toshiba
Datasheet

Specifications of TMP86xy12MG

Package
SSOP30
Rom Types (m=mask,p=otp,f=flash)
M/F
Rom Size
16
Ram Size
512
Driver Led
8
Driver Lcd
-
Spi/sio Channels
1
Uart/sio Channels
1
I2c/sio Channels
-
High-speed Serial Output
-
Adc 8-bit Channels
-
Adc 10-bit Channels
8
Da Converter Channels
-
Timer Counter 18-bit Channel
IGBT
Timer Counter 16-bit Channel
1
Timer Counter 8-bit Channel
2
Motor Channels
-
Watchdog Timer
Y
Dual Clock
Y
Clock Gear
-
Number Of I/o Ports
24
Power Supply (v)
4.5 to 5.5
9.4.8.3 EMG interrupt
9.4.8.4
9.4.8.5
9.4.8.6 Response time between
INTEMG interrupt for some processing, ensure that the interrupt is enabled beforehand.
gency PPG output stop state results in an interrupt being generated again, with the emergency PPG output
stop state reestablished.
whether the timer is operating.
TC7CR3<TC7ST> to 0 and TC7CR3<STM> to 00 to stop the timer, and then set TC7CR2<EMGR> to 1.
Setting EMGR to 1 cancels the stop state only when TC7ST = 0 and STM = 00; ensure that TC7ST = 0
and STM = 00 before setting EMGR to 1.
celed, the timer re-enters the emergency PPG output stop state and an INTEMG interrupt occurs.
ters (TC7CR1, TC7CR2, TC7CR3) before restarting the timer.
stop state and cancel the state before reconfiguring the control registers to restart the timer. Ensure that the
control registers are reconfigured according to the appropriate procedure for configuring timer operation
control.
is up to 10/fc [s].
Canceling the emergency PPG output stop state
Restarting the timer after canceling the emergency PPG output stop state
An EMG interrupt (INTEMG) occurs when an emergency PPG output stop input is accepted. To use an
When the
An INTEMG interrupt occurs whenever a stop input is accepted when EMGIE = 1, regardless of
To cancel the emergency PPG output stop state, ensure that the input on the EMG pin is high, set
If the input on the EMG pin is low and EMGIE = 1 when the emergency PPG output stop state is can-
To restart the timer after canceling the emergency PPG output stop state, reconfigure the control regis-
The timer cannot restart in the emergency PPG output stop state. Monitor the emergency PPG output
The time between a low level input being detected on the
EMG
pin is low with EMGIE set to 1 (
EMG
pin input and PPG outputs being initialized
Page 93
EMG
pin input enabled), an attempt to cancel the emer-
EMG
pin and the PPG outputs being initialized
TMP86CH12MG