TMP86xy12MG Toshiba, TMP86xy12MG Datasheet - Page 96

no-image

TMP86xy12MG

Manufacturer Part Number
TMP86xy12MG
Description
Manufacturer
Toshiba
Datasheet

Specifications of TMP86xy12MG

Package
SSOP30
Rom Types (m=mask,p=otp,f=flash)
M/F
Rom Size
16
Ram Size
512
Driver Led
8
Driver Lcd
-
Spi/sio Channels
1
Uart/sio Channels
1
I2c/sio Channels
-
High-speed Serial Output
-
Adc 8-bit Channels
-
Adc 10-bit Channels
8
Da Converter Channels
-
Timer Counter 18-bit Channel
IGBT
Timer Counter 16-bit Channel
1
Timer Counter 8-bit Channel
2
Motor Channels
-
Watchdog Timer
Y
Dual Clock
Y
Clock Gear
-
Number Of I/o Ports
24
Power Supply (v)
4.5 to 5.5
TC7 pin input
TRGSEL = 0
(2)
causes the counter to start counting and a high level on the TC7 pin causes the counter to be cleared
and the PPG output to be initialized. The counter is stopped while the TC7 pin input is high.
causes the counter to start counting and a low level on the TC7 pin causes the counter to be cleared
and the PPG output to be initialized. The counter is stopped while the TC7 pin input is low.
stop trigger is accepted within a period, the output is immediately initialized and the counter is
stopped).
ignored when the PPG output is active.
enabled with PPG1OE or PPG2OE.
active
started
Count
When TRGSEL is set to 0 to select a falling-edge trigger, a falling edge detected on the TC7 pin
When TRGSEL is set to 1 to select a rising-edge trigger, a rising edge detected on the TC7 pin
In one-time stop mode, the counter accepts a stop trigger but does not accept a start trigger (when a
All triggers (Start and stop) are ignored when the timer is stopped (TC7ST = 0).
Specifying whether triggers are always accepted or ignored when PPG outputs are
The TC7CR1<TRGAM> specifies whether triggers from the TC7 pin are always accepted or
The active/inactive state of the PPG1 or PPG2 pin has meaning only when output on the pin is
Counter
operating
• TRGAM = 0:
• TRGAM = 1:
Triggers from the TC7 pin are always accepted regardless of whether PPG1 and PPG2 out-
puts are active or inactive. A trigger starts or clears/stops the timer and deactivates PPG1 and
PPG2 outputs.
Triggers from the TC7 pin are accepted only when PPG1 and PPG2 outputs are inactive. A
trigger starts or clears/stops the timer. Triggers are ignored when PPG1 and PPG2 outputs are
active.
cleared
Count
Counting stop mode
with the outputs at
the end of the period
Counter
stopped
TC7 pin input
PPG output
Figure 9-11 Trigger Input Signal
started
Count
Counter
operating
One-time
mode
Page 85
TC7 pin input
cleared
TRGSEL = 1
Count
Counter stopped
Initial value
started
Count
Counter
operating
cleared
Count
Counter
stopped
started
Count
TMP86CH12MG
Counter
operating

Related parts for TMP86xy12MG