tmp89fm82t TOSHIBA Semiconductor CORPORATION, tmp89fm82t Datasheet - Page 349

no-image

tmp89fm82t

Manufacturer Part Number
tmp89fm82t
Description
8 Bit Microcontroller
Manufacturer
TOSHIBA Semiconductor CORPORATION
Datasheet
RA000
AD converter control register 1
ADCCR1
(0x0034)
Note 1: Do not perform the following operations on the ADCCR1 register while AD conversion is being executed
Note 2: If you want to disable all analog input channels, set AINEN to "0".
Note 3: Although analog input pins are also used as input/output ports, it is recommended for the purpose of maintaining the
Note 4: When STOP, IDLE0 or SLOW mode is started, ADRS, AMD and AINEN are initialized to "0".
Note 5: When PMD interrupt signal(INTPWM) is generated during setting <AMD> to (0y10), a desinated channel is AD converted
Note 6: After ADRS is set to "1", it is automatically cleared to "0". The time between when ADRS is set to "1" and when it is cleared
Read/Write
Bit Symbol
After reset
AINEN
(ADCCR2<ADBF>="1").
- Changing SAIN
- Setting AINEN to "0"
- Changing AMD (except a forced stop by setting AMD to "00")
- Setting ADRS to "1"
accuracy of AD conversion that you do not execute input/output instructions during AD conversion. Additionally, do not
input widely varying signals into the ports adjacent to analog input pins.
once.
to "0" is a maximum of 4/fcgck [s] when ADCCR2<ACK>="00*", a maximum of 15/fcgck [s] when ADCCR2<ACK>="01*",
and a maximum of 52/fcgck [s] when ADCCR2<ACK>="10*".
ADRS
AMD
SAIN
AD conversion start
AD operating mode
Analog input control
Analog input channel select
ADRS
R/W
7
0
6
0
AMD
R/W
5
0
Page 333
0000:
0001:
0010:
0011:
0100:
0101:
0110:
0111:
1xxx:
00:
01:
10:
11:
0:
1:
0:
1:
-
AD conversion start
AD operation disable, forcibly stop AD operation
Single mode
Trigger start single mode(INTPWM)
Repeat mode
Analog input disable
Analog input enable
AIN0
AIN1
AIN2
AIN3
AIN4
AIN5
AIN6
AIN7
Do not use
AINEN
R/W
4
0
3
0
2
0
SAIN
R/W
1
0
TMP89FM82T
0
0