tmp89fm82t TOSHIBA Semiconductor CORPORATION, tmp89fm82t Datasheet - Page 352

no-image

tmp89fm82t

Manufacturer Part Number
tmp89fm82t
Description
8 Bit Microcontroller
Manufacturer
TOSHIBA Semiconductor CORPORATION
Datasheet
20.3
Functions
RA000
20.3
20.3.1
20.3.2
mode in which AD conversion is performed repeatedly and ttigger start single mode.
The 10-bit AD converter operates in either single mode in which AD conversion is performed only once, repeat
ADCCR1<ADRS>
ADCCR2<ADBF>
Status of ADCDRL
and ADCDRH
ADCCR2<EOCF>
INTADC interrupt
request
Read of ADCDRH
Read of ADCDRL
ADCCR1<ADRS> is automatically cleared after the start of AD conversion. As AD conversion starts,
ADCCR2<ADBF> is set to "1". It is cleared to "0" if AD conversion is finished or if AD conversion is forced to
stop.
and ADCDRH), ADCCR2<EOCF> is set to "1", and the AD conversion finished interrupt (INTADC) is gener-
ated. The AD converted value registers (ADCDRL and ADCDRH) should be usually read according to the
INTADC interrupt processing routine. If the upper side (ADCDRH) of the AD converted value register is read,
ADCCR2<EOCF> is cleared to "0".
designated analog nput pin is AD converted only once.
AD conversion stands by. When INTPWM is generated with AD conversion stands by, AD conversion is begun.
After the start of conversion, ADCCR1<ADRS> is automatically cleared. ADCCR2<ADBF> is set to "1" by the
start of AD conversion. ADCCR2<ADBF> is cleared to "0" after the end of AD conversion or forced stop of AD
Functions
In single mode, the voltage at a designated analog input pin is AD converted only once.
Setting ADCCR1<ADRS> to "1" after setting ADCCR1<AMD> to "01" allows AD conversion to start.
After AD conversion is finished, the conversion result is stored in the AD converted value registers (ADCDRL
In trigger start single mode, the interrupt signal that other peripheral functions generate is made a trigger, a
In TMP89FM82T, PMD interrupt signal (INTPWM) is made a trigger to start AD conversion.
Setting ADCCR1<ADRS> to "1" after setting ADCCR1<AMD> to "10" (trigger start single mode) allows
Single mode
Trigger start single mode
Note:Do not perform the following operations on the ADCCR1 register when AD conversion is being executed
(ADCCR2<ADBF>="1"). If the following operations are performed, there is the possibility that AD con-
version may not be executed properly.
・ Changing the ADCCR1<SAIN> setting
・ Setting ADCCR1<AINEN> to "0"
・ Changing the ADCCR1<AMD> setting (except a forced stop by setting AMD to "00")
・ Setting ADCCR1<ADRS> to "1"
AD conversion start
Indeterminate
Figure 20-2 Single Mode
Result of the first conversion
Read of conversion result
Read of conversion result
Page 336
AD conversion start
Result of the second conversion
Read of conversion result
Read of conversion result
Clearing EOCF based on
the conversion result
TMP89FM82T

Related parts for tmp89fm82t