Table 35: Program Enhanced Configuration Register Command Bus Cycles
Note:
9.4
Table 36: Read Mode Command Bus Cycles
9.4.1
April 2008
309823-10
Program Enhanced Configuration Register
Read Array
Read Status Register
Read Device Information
CFI Query
Command
Command
To program the Enhanced Configuration Register, the desired settings for ECR[15:0]
are placed on the address bus. The setup command (0060h) is driven on the data bus.
Upon issuing the setup command, the device/addressed partition is automatically
changed to Read Status Register mode.
Next, the Confirm command (0004h) is driven on the data bus. After issuing the
Confirm command, the addressed partition is automatically switched to Read Array
mode.
This command functions independently of the applied VPP voltage.
Since the desired register value is placed on the address lines, any hardware-
connection offsets between the host’s address outputs and the flash device’s address
inputs must be considered, similar to programming the RCR.
Read Operations
The following types of data can be read from the device: array data, device
information, CFI data, and device status Upon power-up or return from reset, the
device defaults to Read Array mode. To change the device’s read mode, the appropriate
command must be issued to the device.
shows the command codes used to configure the device for the desired read mode. The
following sections describe each read mode.
Read Array
Upon power-up or exit from reset, the device defaults to Read Array mode. Issuing the
Read Array command places the addressed partition in Read Array mode. Subsequent
reads output array data. The addressed partition remains in Read Array mode until a
different read command is issued, or a program or erase operation is performed in that
partition, in which case, the read mode is automatically changed to Read Status.
To changea partition to Read Array mode while it is programming or erasing, first issue
the Suspend command. After the operation has been suspended, issue the Read Array
command to the partition. When the program or erase operation is subsequently
resumed, the read state of the partition will not change. To change the read state of
the partition to Status read mode, issue a Read Status command to the partition.
®
Cellular Memory (M18)
Partition Address
Partition Address
Partition Address
Partition Address
Address Bus
Address Bus
Register Data
Setup Write Cycle
Setup Write Cycle
Table 36, “Read Mode Command Bus Cycles”
00FFh
0070h
0090h
0098h
Data Bus
Data Bus
0060h
---
---
---
---
Address Bus
Register Data
Address Bus
Confirm Write Cycle
Confirm Write Cycle
---
---
---
---
Data Bus
Data Bus
0004h
Datasheet
81
Related parts for PF38F5070M0Q0B0
Image
Part Number
Description
Manufacturer
Datasheet
Request
R
Part Number:
Description:
Numonyx Wireless Flash Memory (W18)
Manufacturer:
NUMONYX [Numonyx B.V]
Datasheet:
Part Number:
Description:
Numonyx StrataFlash Wireless Memory
Manufacturer:
NUMONYX [Numonyx B.V]
Datasheet:
Part Number:
Description:
8 Mbit, low voltage, Page-Erasable Serial Flash memory with byte alterability and a 50 MHz SPI bus interface
Manufacturer:
NUMONYX [Numonyx B.V]
Datasheet:
Part Number:
Description:
128 Mbit (8 Mb 16, multiple bank, multilevel interface, burst) 1.8 V supply, secure Flash memories
Manufacturer:
NUMONYX [Numonyx B.V]
Datasheet:
Part Number:
Description:
64-Mbit, dual I/O, 4-Kbyte subsector erase, serial flash memory with 75 MHz SPI bus interface
Manufacturer:
NUMONYX [Numonyx B.V]
Datasheet:
Part Number:
Description:
512 Kbit, serial Flash memory, 50 MHz SPI bus interface
Manufacturer:
NUMONYX [Numonyx B.V]
Datasheet:
Part Number:
Description:
1 Mbit, serial Flash memory, 50 MHz SPI bus interface
Manufacturer:
NUMONYX [Numonyx B.V]
Datasheet:
Part Number:
Description:
16 Mbit, serial Flash memory, 75 MHz SPI bus interface
Manufacturer:
NUMONYX [Numonyx B.V]
Datasheet:
Part Number:
Description:
Wireless Flash Memory (W18/W30 SCSP)
Manufacturer:
NUMONYX [Numonyx B.V]
Datasheet:
Part Number:
Description:
128 Mbit (16Mb x8 or 8Mb x16, Multiple Bank, Page, Boot Block) 3V supply Flash memory
Manufacturer:
NUMONYX [Numonyx B.V]
Datasheet:
Part Number:
Description:
128 Mbit (8 Mb x 16, multiple bank, page, dual boot) 3 V supply Flash memory
Manufacturer:
NUMONYX [Numonyx B.V]
Datasheet:
Part Number:
Description:
32 Mbit (4Mb x8 or 2Mb x16, Dual Bank 8:24, Boot Block) 3V Supply Flash Memory
Manufacturer:
NUMONYX [Numonyx B.V]
Datasheet:
Part Number:
Description:
32 Mbit (4Mb x8 or 2Mb x16, Dual Bank 16:16, Boot Block) 3V Supply Flash Memory
Manufacturer:
NUMONYX [Numonyx B.V]
Datasheet:
Part Number:
Description:
64 Mbit (8Mb x8 or 4Mb x16, Multiple Bank, Page, Boot Block) 3V Supply Flash Memory
Manufacturer:
NUMONYX [Numonyx B.V]
Datasheet:
Part Number:
Description:
64 Mbit (4Mb x16, Multiple Bank, Page, Boot Block) 3V Supply Flash Memory
Manufacturer:
NUMONYX [Numonyx B.V]
Datasheet: