MC68306 Motorola, MC68306 Datasheet - Page 122

no-image

MC68306

Manufacturer Part Number
MC68306
Description
Integrated EC000 Processor
Manufacturer
Motorola
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MC68306AG16B
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Part Number:
MC68306AG20B
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Part Number:
MC68306CEH16B
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Part Number:
MC68306EH16B
Manufacturer:
DATEL
Quantity:
87
Part Number:
MC68306EH16B
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Part Number:
MC68306EH16BR2
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Part Number:
MC68306FC16
Manufacturer:
FREESCALE
Quantity:
12 388
Part Number:
MC68306FC16
Manufacturer:
MOTOROLA
Quantity:
672
Part Number:
MC68306FC16A
Manufacturer:
IDT
Quantity:
924
Part Number:
MC68306FC16A
Manufacturer:
MOTOROLA
Quantity:
1 045
Part Number:
MC68306FC16A
Manufacturer:
MOTOROLA/摩托罗拉
Quantity:
20 000
Part Number:
MC68306FC16B
Manufacturer:
MOTOROLA/摩托罗拉
Quantity:
20 000
6.3.4 Multidrop Mode
A channel can be programmed to operate in a wakeup mode for multidrop or
multiprocessor applications. Functional timing information for the multidrop mode is shown
in Figure 6-8. The mode is selected by setting bits 3 and 4 in mode register 1 (DUMR1).
This mode of operation allows the master station to be connected to several slave stations
(maximum of 256). In this mode, the master transmits an address character followed by a
block of data characters targeted for one of the slave stations. The slave stations have
their channel receivers disabled. However, they continuously monitor the data stream sent
out by the master station. When an address character is sent by the master, the slave
receiver channel notifies its respective CPU by setting the RxRDY bit in the DUSR and
generating an interrupt (if programmed to do so). Each slave station CPU then compares
the received address to its station address and enables its receiver if it wishes to receive
the subsequent data characters or block of data from the master station. Slave stations
not addressed continue to monitor the data stream for the next address character. Data
fields in the data stream are separated by an address character. After a slave receives a
block of data, the slave station's CPU disables the receiver and initiates the process
again.
6-14
Figure 6-7. Looping Modes Functional Diagram
CPU
CPU
CPU
DISABLED
DISABLED
DISABLED
MC68306 USER'S MANUAL
Rx
Tx
Rx
Rx
Tx
Tx
(c) Remote Loopback
(b) Local Loopback
(a) Automatic Echo
DISABLED
DISABLED
DISABLED
DISABLED
DISABLED
RxDx
INPUT
TxDx
OUTPUT
RxDx
INPUT
TxDx
OUTPUT
RxDx
INPUT
TxDx
OUTPUT
MOTOROLA