T-8110L AGERE [Agere Systems], T-8110L Datasheet - Page 110

no-image

T-8110L

Manufacturer Part Number
T-8110L
Description
Manufacturer
AGERE [Agere Systems]
Datasheet
Ambassador T8110L H.100/H.110 Switch
11 Test and Diagnostics
11.1 Diagnostics Control Registers
11.1.3 State Counter Modes Registers
The state counter modes registers control state counter diagnostics, including the breaking of state counter carry
chains, using /FR_COMP as the internal frame reference, and allowing the state counter to roll over early via a
modulo function. For more details, refer to Section 11.2 on page 112.
Table 92. State Counter Modes Registers
11.1.4 Miscellaneous Diagnostics Low Register
The miscellaneous diagnostics low register: bits 2 and 1 allow direct reset of the APLL2 and APLL1 feedback divid-
ers. Bit 0 controls the TST input of the power-on reset cell.
Table 93. Miscellaneous Diagnostics Low Register
110
Address
Address
0x00144 Diag4, State Counter
0x00145 Diag5, State Counter
0x00146 Diag6, Miscellaneous
Byte
Byte
Modes Low
Modes High
Diagnostics Low
Name
Name
(continued)
Bit(s)
7:3
2
1
0
Bit(s) Mnemonic
7:0
7:6
2:0
5
4
3
(continued)
Mnemonic
Reserved
Reserved
FB2SB
FB1SB
Reserved
SCMSB
SCMLR
FRMSB
SCULP
SCLSB
Value
LLLL LLLL Lower 8 bits of state counter modulo load
00
0
1
0
1
Value
LLL
00
0
1
0
1
0
1
NOP (default).
APLL2 feedback divider reset inactive (default).
APLL2 feedback divider reset active.
APLL1 feedback divider reset inactive (default).
APLL1 feedback divider reset active.
value.
NOP (default).
Normal carry chain operation (default).
Break state counter carry chains.
Normal internal frame operation (default).
Use /FR_COMP as internal frame.
Normal counting (default).
State counter modulo counting.
Upper 3 bits of state counter modulo load
value.
Function
Function
Agere Systems Inc.
February 2004