DS1874T+ Maxim Integrated Products, DS1874T+ Datasheet - Page 42

IC CTLR SFP+ ANLG LDD 28-TQFN

DS1874T+

Manufacturer Part Number
DS1874T+
Description
IC CTLR SFP+ ANLG LDD 28-TQFN
Manufacturer
Maxim Integrated Products
Type
Laser Diode Controllerr
Datasheet

Specifications of DS1874T+

Number Of Channels
1
Voltage - Supply
2.85 V ~ 3.9 V
Current - Supply
2.5mA
Operating Temperature
-40°C ~ 95°C
Package / Case
28-WFQFN Exposed Pad
Mounting Type
Surface Mount
Number Of Outputs
5
Duty Cycle (max)
50 %
Output Voltage
0 V to 3.9 V
Mounting Style
SMD/SMT
Switching Frequency
0 KHz to 400 KHz
Operating Supply Voltage
2.85 V to 3.9 V
Supply Current
2.5 mA to 10 mA
Maximum Operating Temperature
+ 95 C
Fall Time
300 ns
Minimum Operating Temperature
- 40 C
Rise Time
300 ns
Synchronous Pin
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
90-1874T+000
SFP+ Controller with Digital LDD Interface
Lower Memory, Register 70h: ALARM
42
70h
______________________________________________________________________________________
POWER-ON VALUE
READ ACCESS
WRITE ACCESS
MEMORY TYPE
TEMP HI
BIT 7
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
TEMP HI: High-alarm status for temperature measurement.
0 = (Default) Last measurement was equal to or below threshold setting.
1 = Last measurement was above threshold setting.
TEMP LO: Low-alarm status for temperature measurement.
0 = (Default) Last measurement was equal to or above threshold setting.
1 = Last measurement was below threshold setting.
VCC HI: High-alarm status for V
0 = (Default) Last measurement was equal to or below threshold setting.
1 = Last measurement was above threshold setting.
VCC LO: Low-alarm status for V
point value. It clears itself when a V
0 = Last measurement was equal to or above threshold setting.
1 = (Default) Last measurement was below threshold setting.
MON1 HI: High-alarm status for MON1 measurement.
0 = (Default) Last measurement was equal to or below threshold setting.
1 = Last measurement was above threshold setting.
MON1 LO: Low-alarm status for MON1 measurement.
0 = (Default) Last measurement was equal to or above threshold setting.
1 = Last measurement was below threshold setting.
MON2 HI: High-alarm status for MON2 measurement.
0 = (Default) Last measurement was equal to or below threshold setting.
1 = Last measurement was above threshold setting.
MON2 LO: Low-alarm status for MON2 measurement.
0 = (Default) Last measurement was equal to or above threshold setting.
1 = Last measurement was below threshold setting.
TEMP LO
10h
All
N/A
Volatile
VCC HI
3
CC
CC
VCC LO
measurement.
CC
measurement. This bit is set when the V
measurement is completed and the value is above the low threshold.
MON1 HI
MON1 LO
CC
supply is below the POA trip
MON2 HI
MON2 LO
BIT 0