D13002F16V Renesas Electronics America, D13002F16V Datasheet - Page 82

IC H8/3002 ROMLESS 100QFP

D13002F16V

Manufacturer Part Number
D13002F16V
Description
IC H8/3002 ROMLESS 100QFP
Manufacturer
Renesas Electronics America
Series
H8® H8/300Hr
Datasheet

Specifications of D13002F16V

Core Processor
H8/300H
Core Size
16-Bit
Speed
16MHz
Connectivity
SCI
Peripherals
DMA, PWM, WDT
Number Of I /o
38
Program Memory Type
ROMless
Ram Size
512 x 8
Voltage - Supply (vcc/vdd)
2.7 V ~ 5.5 V
Data Converters
A/D 8x10b
Oscillator Type
Internal
Operating Temperature
-20°C ~ 75°C
Package / Case
100-QFP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Program Memory Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
D13002F16V
Manufacturer:
Renesas Electronics America
Quantity:
10 000
4.1 Overview
4.1.1 Exception Handling Types and Priority
As table 4-1 indicates, exception handling may be caused by a reset, trap instruction, or interrupt.
Exception handling is prioritized as shown in table 4-1. If two or more exceptions occur
simultaneously, they are accepted and processed in priority order. Trap instruction exceptions are
accepted at all times in the program execution state.
Table 4-1 Exception Types and Priority
Priority Exception Type
High
Low
4.1.2 Exception Handling Operation
Exceptions originate from various sources. Trap instructions and interrupts are handled as follows.
1.
2.
3.
For a reset exception, steps 2 and 3 above are carried out.
The program counter (PC) and condition code register (CCR) are pushed onto the stack.
The CCR interrupt mask bit is set to 1.
A vector address corresponding to the exception source is generated, and program execution
starts from that address.
Reset
Interrupt
Trap instruction (TRAPA) Started by execution of a trap instruction (TRAPA)
Section 4 Exception Handling
Start of Exception Handling
Starts immediately after a low-to-high transition at the RES pin
Interrupt requests are handled when execution of the current
instruction or handling of the current exception is completed
65

Related parts for D13002F16V