AD9923BBCZ Analog Devices Inc, AD9923BBCZ Datasheet - Page 51

no-image

AD9923BBCZ

Manufacturer Part Number
AD9923BBCZ
Description
Manufacturer
Analog Devices Inc
Datasheet

Specifications of AD9923BBCZ

Analog Front End Type
CCD
Analog Front End Category
Video
Interface Type
Serial (3-Wire)
Sample Rate
36MSPS
Input Voltage Range
0.7V
Operating Supply Voltage (min)
2.7V
Operating Supply Voltage (typ)
3V
Operating Supply Voltage (max)
3.6V
Resolution
12b
Number Of Adc's
1
Power Supply Type
Analog/Digital
Operating Temp Range
-25C to 85C
Operating Temperature Classification
Commercial
Mounting
Surface Mount
Pin Count
105
Package Type
CSPBGA
Number Of Channels
1
Lead Free Status / RoHS Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AD9923BBCZ
Manufacturer:
ADI
Quantity:
519
Part Number:
AD9923BBCZ
Manufacturer:
AD
Quantity:
1 000
Part Number:
AD9923BBCZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
AD9923BBCZR
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
AD9923BBCZRL
Manufacturer:
RENESAS
Quantity:
1 723
Part Number:
AD9923BBCZRL
Manufacturer:
ADI/亚德诺
Quantity:
20 000
SUBCK
SHUT0 TO SHUT3
VSUB
VSG1
SHUT0 TO SHUT3 1
VD
1
VSUB OPERATION:
1. ACTIVE POLARITY IS DEFINED BY VSUBPOL (ABOVE EXAMPLE IS VSUB ACTIVE HIGH).
2. ON POSITION IS PROGRAMMABLE, MODE 0 TURNS ON AT THE START OF EXPOSURE, MODE 1 TURNS ON AT THE START OF READOUT.
3. OFF POSITION OCCURS AT END OF READOUT.
4. OPTIONAL VSUB KEEP-ON MODE LEAVES THE VSUB ACTIVE AT THE END OF THE READOUT.
SUBCK
TRIGGER
SUBCK
VSUB
VSG
VSG
VD
VD
SHUT_ON = 1
SHUT PROGRAMMABLE SETTINGS:
1. ACTIVE POLARITY. DEFINES THE LOGIC LEVEL DURING ON TIME. ABOVE EXAMPLE USES ACTIVE POLARITY = 1.
2. ON POSITION IS PROGRAMMABLE DURING ANY EXPOSURE FIELD. ABOVE EXAMPLE USES SHUTON_FD = 1.
3. OFF POSITION IS PROGRAMMABLE DURING ANY EXPOSURE FIELD. ABOVE EXAMPLE USES SHUTOFF_FD = 2.
SHUT PROGRAMMABLE SETTINGS:
1. ACTIVE POLARITY. DEFINES THE LOGIC LEVEL DURING ON TIME. ABOVE EXAMPLE USES ACTIVE POLARITY = 1.
2. ON POSITION IS PROGRAMMABLE DURING ANY EXPOSURE FIELD. ABOVE EXAMPLE USES SHUTON_FD = 1.
3. OFF POSITION IS PROGRAMMABLE DURING ANY EXPOSURE FIELD. ABOVE EXAMPLE USES SHUTOFF_FD = 2.
OFF STATE
(ON)
2
MODE 0
OFF STATE
ON STATE
EXPOSURE
EXPOSURE
AND SHUT
TRIGGER
TRIGGER
Figure 69. Manual Control of SHUT0 to SHUT3 Signals
Figure 68. SHUT0 to SHUT3 Signal Programmability
Figure 67. VSUB0, VSUB1 Signal Programmability
t
EXP
EXPOSURE FIELD 0
EXPOSURE FIELD 0
Rev. 0 | Page 51 of 88
MODE 1
2
EXPOSURE FIELD 1
EXPOSURE FIELD 1
2
SHUT_ON = 0
READOUT
ON STATE
(OFF)
t
t
EXP
EXP
EXPOSURE FIELD 2
EXPOSURE FIELD 2
3
3
4
AD9923

Related parts for AD9923BBCZ