Input Impedance
400 KOhm
Measurement Error
0.1%
Voltage - I/o High
2.4V
Voltage - I/o Low
0.4V
Current - Supply
22mA
Voltage - Supply
3 V ~ 3.6 V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
40-WFQFN, CSP Exposed Pad
Meter Type
3 Phase
Supply Voltage Range
3V To 3.6V
Operating Temperature Range
-40°C To +85°C
Digital Ic Case Style
LFCSP
No. Of Pins
40
Msl
MSL 1 - Unlimited
Peak Reflow Compatible (260 C)
Yes
Supply Voltage Min
3V
Rohs Compliant
Yes
Leaded Process Compatible
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ADE7878ACPZ
Manufacturer:
ST
Quantity:
7 500
Part Number:
ADE7878ACPZ
Manufacturer:
ADI
Quantity:
30
Part Number:
ADE7878ACPZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
ADE7878ACPZ-RL
Manufacturer:
AD
Quantity:
210
Part Number:
ADE7878ACPZ-RL
Manufacturer:
RICOH
Quantity:
4 100
the voltage channel. The voltage rms values are signed 24-bit
values and they are stored into the Registers AVRMS, BVRMS, and
CVRMS. The update rate of the current rms measurement is 8 kHz.
With the specified full-scale analog input signal of 0.5 V, the
ADC produces an output code that is approximately ±5,928,256.
The equivalent rms value of a full-scale sinusoidal signal is
4,191,910 (0x3FF6A6), independent of the line frequency.
The accuracy of the voltage rms is typically 0.1% error from the
full-scale input down to 1/1000 of the full-scale input. Additionally,
this measurement has a bandwidth of 2 kHz. It is recommended
to read the rms registers synchronous to the voltage zero crossings
VOLTAGE SIGNAL
FROM HPF
Figure 58. Voltage RMS Signal Processing
0xA58AC0 =
0x5A7540 =
–5,928,256
x
5,928,256
2
Rev. D | Page 43 of 96
0V
LPF
2
7
xVRMSOS[23:0]
to ensure stability. The IRQ1 interrupt can be used to indicate
when a zero crossing has occurred (see the
The settling time for the V rms measurement is 440 ms for both
50 Hz and 60 Hz input signals. The V rms measurement is the
time it takes for the rms register to reflect the value at the input
to the voltage channel when starting from 0.
As stated in the Current Waveform Gain Registers section, the
serial ports of the ADE78xx work on 32-, 16-, or 8-bit words.
Similar to the register presented in Figure 34, the AVRMS,
BVRMS, and CVRMS 24-bit signed registers are accessed as
32-bit registers with the eight MSBs padded with 0s.
ADE7854/ADE7858/ADE7868/ADE7878
xVRMS[23:0]
Interrupts
section).