HD64F3664FPV Renesas Electronics America, HD64F3664FPV Datasheet - Page 235

IC H8/3664 MCU FLASH 32K 64LQFP

HD64F3664FPV

Manufacturer Part Number
HD64F3664FPV
Description
IC H8/3664 MCU FLASH 32K 64LQFP
Manufacturer
Renesas Electronics America
Series
H8® H8/300H Tinyr
Datasheets

Specifications of HD64F3664FPV

Core Size
16-Bit
Program Memory Size
32KB (32K x 8)
Oscillator Type
External
Core Processor
H8/300H
Speed
16MHz
Connectivity
I²C, SCI
Peripherals
PWM, WDT
Number Of I /o
29
Program Memory Type
FLASH
Ram Size
2K x 8
Voltage - Supply (vcc/vdd)
3 V ~ 5.5 V
Data Converters
A/D 8x10b
Operating Temperature
-20°C ~ 75°C
Package / Case
64-LQFP
No. Of I/o's
29
Ram Memory Size
2KB
Cpu Speed
16MHz
No. Of Timers
4
Digital Ic Case Style
LQFP
Supply Voltage
RoHS Compliant
Controller Family/series
H8/300H
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD64F3664FPV
Manufacturer:
MURATA
Quantity:
34 000
Part Number:
HD64F3664FPV
Manufacturer:
HD
Quantity:
465
Part Number:
HD64F3664FPV
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Part Number:
HD64F3664FPV
Manufacturer:
RENESAS
Quantity:
1 000
Part Number:
HD64F3664FPV
Manufacturer:
RENESAS
Quantity:
1 000
Part Number:
HD64F3664FPV
Manufacturer:
RENESAS
Quantity:
1 000
Part Number:
HD64F3664FPV
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Part Number:
HD64F3664FPV
0
[4]
Figure 14.13 Sample Serial Reception Flowchart (Clocked Synchronous Mode)
Yes
No
Read receive data in RDR
Clear OER flag in SSR to 0
Clear RE bit in SCR3 to 0
Read RDRF flag in SSR
Overrun error processing
Read OER flag in SSR
All data received?
Error processing
Start reception
RDRF = 1
OER = 1
<End>
<End>
Yes
No
No
(Continued below)
Error processing
Yes
[1]
[2]
[3]
[4]
[1]
[2]
[3]
[4]
Read the OER flag in SSR to determine if
there is an error. If an overrun error has
occurred, execute overrun error processing.
Read SSR and check that the RDRF flag is
set to 1, then read the receive data in RDR.
When data is read from RDR, the RDRF
flag is automatically cleared to 0.
To continue serial reception, before the
MSB (bit 7) of the current frame is received,
reading the RDRF flag and reading RDR
should be finished. When data is read from
RDR, the RDRF flag is automatically
cleared to 0.
If an overrun error occurs, read the OER
flag in SSR, and after performing the
appropriate error processing, clear the OER
flag to 0. Reception cannot be resumed if
the OER flag is set to 1.
Rev. 5.00, 03/04, page 207 of 388