UPD78F0551MA-FAA-AX Renesas Electronics America, UPD78F0551MA-FAA-AX Datasheet - Page 335

no-image

UPD78F0551MA-FAA-AX

Manufacturer Part Number
UPD78F0551MA-FAA-AX
Description
MCU 8BIT 16-SSOP
Manufacturer
Renesas Electronics America
Series
78K0/Kx2-Lr
Datasheet

Specifications of UPD78F0551MA-FAA-AX

Core Processor
78K/0
Core Size
8-Bit
Speed
10MHz
Connectivity
I²C, LIN, UART/USART
Peripherals
LVD, POR, PWM, WDT
Number Of I /o
9
Program Memory Size
8KB (8K x 8)
Program Memory Type
FLASH
Ram Size
512 x 8
Voltage - Supply (vcc/vdd)
1.8 V ~ 5.5 V
Data Converters
A/D 4x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
*
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
78K0/Kx2-L
R01UH0028EJ0400 Rev.4.00
Sep 27, 2010
Note Bits 2 and 3 are write-only.
Cautions 1. The settings of LVS50 and LVR50 are valid in other than PWM mode.
Remarks 1. In PWM mode, PWM output is made inactive by clearing TCE50 to 0.
Address: FF6BH
Symbol
TMC50
Figure 7-9. Format of 8-Bit Timer Mode Control Register 50 (TMC50) (78K0/KB2-L, 78K0/KC2-L Only)
2. If LVS50 and LVR50 are read, the value is 0.
3. The values of the TMC506, LVS50, LVR50, TMC501, and TOE50 bits are reflected at the TO50 output
2. Perform <1> to <4> below in the following order, not at the same time.
3. When TCE50 = 1, setting the other bits of TMC50 is prohibited.
4. The actual TO50/TI50/P17 pin output is determined depending on PM17 and P17 besides TO50
regardless of the value of TCE50.
<1> Set TMC501, TMC506:
<2> Set TOE50 to enable output:
<3> Set LVS50, LVR50 (refer to Caution 1): Timer F/F setting
<4> Set TCE50
output.
TMC506
TMC501
TOE50
TCE50
TCE50
LVS50
<7>
0
1
0
1
0
0
1
1
0
1
0
1
After reset: 00H
After clearing to 0, count operation disabled (counter stopped)
Count operation start
Mode in which clear & start occurs on a match between TM50 and CR50
PWM (free-running) mode
Inversion operation disabled
Inversion operation enabled
Output disabled (TO50 output is low level)
Output enabled
TMC506
LVR50
6
0
1
0
1
In other modes (TMC506 = 0)
R/W
No change
Timer output F/F clear (0) (default value of TO50 output: low level)
Timer output F/F set (1) (default value of TO50 output: high level)
Setting prohibited
Timer F/F control
Note
5
0
CHAPTER 7 8-BIT TIMER/EVENT COUNTERS 50 AND 51
TM50 operating mode selection
TM50 count operation control
4
0
Timer output control
Timer output F/F status setting
Operation mode setting
Timer output enable
LVS50
<3>
Active-high
Active-low
In PWM mode (TMC506 = 1)
LVR50
<2>
Active level selection
TMC501
1
TOE50
<0>
321