Specifications of HD64F36077GHV

No. Of I/o's
47
Ram Memory Size
4KB
Cpu Speed
20MHz
No. Of Timers
4
Digital Ic Case Style
LQFP
Supply Voltage Range
4.5V
Core Size
16bit
Program Memory Size
56KB
Oscillator Type
External Only
Controller Family/series
H8/300H
Peripherals
ADC
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD64F36077GHV
Manufacturer:
RENESAS
Quantity:
340
Part Number:
HD64F36077GHV
Manufacturer:
Renesas
Quantity:
200
Part Number:
HD64F36077GHV
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Section 10 Realtime Clock (RTC)
10.4
10.4.1
The RTC registers that store second, minute, hour, and day-of week data are not reset by a RES
input. Therefore, all registers must be set to their initial values after power-on. Once the register
setting are made, the RTC provides an accurate time as long as power is supplied regardless of a
RES input.
10.4.2
Figure 10.3 shows the procedure for the initial setting of the RTC. To set the RTC again, also
follow this procedure.
Rev. 1.00 Sep. 16, 2005 Page 168 of 490
REJ09B0216-0100
Operation
Initial Settings of Registers after Power-On
Initial Setting Procedure
Set RTCCSR, RSECDR,
RMINDR,RHRDR,
RWKDR,12/24 in
RTCCR1, and PM
RUN in RTCCR1=0
RUN in RTCCR1=1
RST in RTCCR1=1
RST in RTCCR1=0
Figure 10.3 Initial Setting Procedure
RTC operation is stopped.
RTC registers and clock count
controller are reset.
Clock output and clock source are
selected and second, minute, hour,
day-of-week,operating mode, and
a.m/p.m are set.
RTC operation is started.