8808A 120V Fluke Electronics, 8808A 120V Datasheet - Page 45

DMM 5.5 RES RS-232 INTERFACE

8808A 120V

Manufacturer Part Number
8808A 120V
Description
DMM 5.5 RES RS-232 INTERFACE
Manufacturer
Fluke Electronics
Type
Digital (DMM)r
Datasheets

Specifications of 8808A 120V

Includes
Test Leads
Style
Bench
Display Digits
5.5
Display Type
VFD, Dual
Display Count
200000
Function
Voltage, Current, Resistance, Frequency
Functions, Extra
Continuity, dB, Diode Test
Features
Hold, Min/Max, RS-232 Port
Ranging
Auto/Manual
Response
True RMS
Lead Free Status / RoHS Status
Not applicable / RoHS non-compliant
Other names
614-1068
Frequency Ranging
Measuring Resistance
2-Wire Resistance Measurement
Frequency measurements are automatically ranged so that a frequency measurement is
always displayed with maximum resolution.
To select a range manually, press F to select the frequency function, and then press
U or V to select a range manually. Manual ranging can be performed on readings
displayed in the primary display only.
If you manually select a frequency range and the measurement exceeds the full-scale
value of that range, 0L is displayed to indicate an overload. If the frequency is lower than
20 Hz, UL is displayed. Refer to the “Electrical Specifications” section in Chapter 1 for
frequency ranges and full-scale values.
The Meter offers 2-wire and 4-wire ohms measurement. Press O to toggle between 2-
wire and 4-wire measurement modes. The Meter displays 2*4 Wire at 2 wire or 2x4 wire
resistance measurement and displays 4 Wire at 4 wire resistance measurement.
To perform a 2-wire resistance measurement:
1. Connect test leads between the Meter and the circuit under test as shown in
2. If required, press O to select 2-wire resistance measurement mode. 2*4 Wire is
Figure 3-5.
displayed.
The function and measurement are displayed.
Figure 3-5. 2-Wire Resistance Measurement
Operating the Meter from the Front Panel
Selecting a Measurement Function
2W/4W
1000V
750V
mA
LO
HI
200 mA
MAX
MAX
V
INPUT
1000 V
600 V
500 V pk
10 A
MAX
1V
CAT I
CAT II
SENSE
4 W
300V
10A
LO
HI
eue11.eps
3-11
3