AM79C976KI AMD (ADVANCED MICRO DEVICES), AM79C976KI Datasheet - Page 127

no-image

AM79C976KI

Manufacturer Part Number
AM79C976KI
Description
Manufacturer
AMD (ADVANCED MICRO DEVICES)
Datasheet

Specifications of AM79C976KI

Operating Supply Voltage (typ)
3.3V
Operating Supply Voltage (min)
2.97V
Operating Supply Voltage (max)
3.63V
Operating Temperature Classification
Industrial
Mounting
Surface Mount
Pin Count
208
Lead Free Status / RoHS Status
Not Compliant
AUTOPOLL2:
Offset 08Ch
This register controls the automatic polling of a user-
selectable external PHY register, AP_REG2.
9/14/00
14-13
12-8
4-0
Bit
15
7
6
5
AP_REG2_ADDR
AP_PHY2_ADDR
AP_PHY2_DFLT
AP_PRE_SUP2
AP_REG2_EN
Auto-Poll2 Register
Name
RES
RES
Enable Bit for Autopoll Register 2. When this bit and the Auto-Poll External PHY bit (APEP) in
CMD3 are both set to 1, the Auto-Poll State Machine periodically reads the external PHY
register selected by the AP_PHY2_ADDR and AP_REG2_ADDR fields and sets the APINT2
interrupt bit if it detects a change in the register’s contents.
Reserved locations. Written as zeros and read as undefined.
AP_REG2 Address. This field contains the register number of an external PHY register that
the Auto-Poll State Machine will periodically read if the AP_REG2_EN bit in this register and
the APEP bit (CMD3, bit 24) is set.
Reserved location. Written as zero and read as undefined.
Auto-Poll Preamble Suppression. If this bit is set to 1, the Auto-Poll State Machine will
suppress the preambles of the MII Management Frames that it uses to periodically read the
external PHY register selected by the AP_PHY2_ADDR and AP_REG2_ADDR fields.
This bit is ignored when the AP_PHY2_DFLT bit is set.
Auto-Poll PHY2 Default. When this bit is set, the Auto-Poll State Machine ignores the contents
of the AP_PHY2_ADDR and AP_PRE_SUP2 fields and uses the AP_PHY0_ADDR field for
the address of the PHY device to be polled. If this bit is set, the Auto-Poll State Machine will
suppress preambles only if the Port Manager has determined that the default external PHY
can accept MII Management Frames without preambles. (The Port Manager examines bit 6 in
register 1 of the default PHY to make this determination.)
Auto-Poll PHY2 Address. This field contains the address of the external PHY that contains
AP_REG2.
This bit is ignored when the AP_PHY2_DFLT bit is set.
Table 34. AUTOPOLL2: Auto-Poll2 Register
P R E L I M I N A R Y
Am79C976
All bits in this register are set to their default values by
H_RESET. All bits are also set to their default values
before EEPROM data are loaded or after an EEPROM
read failure.
The default value for all bits in this register is 0.