EP2SGX30DF780C5N Altera, EP2SGX30DF780C5N Datasheet - Page 133

IC STRATIX II GX 30K 780-FBGA

EP2SGX30DF780C5N

Manufacturer Part Number
EP2SGX30DF780C5N
Description
IC STRATIX II GX 30K 780-FBGA
Manufacturer
Altera
Series
Stratix® II GXr
Datasheet

Specifications of EP2SGX30DF780C5N

Number Of Logic Elements/cells
33880
Number Of Labs/clbs
1694
Total Ram Bits
1369728
Number Of I /o
361
Voltage - Supply
1.15 V ~ 1.25 V
Mounting Type
Surface Mount
Operating Temperature
0°C ~ 70°C
Package / Case
780-FBGA
Family Name
Stratix II GX
Number Of Logic Blocks/elements
33880
# I/os (max)
361
Frequency (max)
609.76MHz
Process Technology
SRAM
Operating Supply Voltage (typ)
1.2V
Logic Cells
33880
Ram Bits
1369728
Operating Supply Voltage (min)
1.15V
Operating Supply Voltage (max)
1.25V
Operating Temp Range
0C to 85C
Operating Temperature Classification
Commercial
Mounting
Surface Mount
Pin Count
780
Package Type
FC-FBGA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Number Of Gates
-
Lead Free Status / Rohs Status
Compliant
Other names
544-1754

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EP2SGX30DF780C5N
Manufacturer:
ALTERA
0
Part Number:
EP2SGX30DF780C5N
Manufacturer:
ALTERA/阿尔特拉
Quantity:
20 000
Altera Corporation
October 2007
Table 2–32
strength control.
Open-Drain Output
Stratix II GX devices provide an optional open-drain (equivalent to an
open collector) output for each I/O pin. This open-drain output enables
the device to provide system-level control signals (for example, interrupt
and write enable signals) that can be asserted by any of several devices.
Bus Hold
Each Stratix II GX device I/O pin provides an optional bus-hold feature.
The bus-hold circuitry can hold the signal on an I/O pin at its last-driven
state. Since the bus-hold feature holds the last-driven state of the pin until
the next input signal is present, an external pull-up or pull-down resistor
is not needed to hold a signal level when the bus is tri-stated.
Note to
(1)
3.3-V LVTTL
3.3-V LVCMOS
2.5-V LVTTL/LVCMOS
1.8-V LVTTL/LVCMOS
1.5-V LVCMOS
SSTL-2 Class I
SSTL-2 Class II
SSTL-18 Class I
SSTL-18 Class II
HSTL-18 Class I
HSTL-18 Class II
HSTL-15 Class I
HSTL-15 Class II
Table 2–32. Programmable Drive Strength
The Quartus II software default current setting is the maximum setting for each
I/O standard.
I/O Standard
Table
shows the possible settings for the I/O standards with drive
2–32:
I
Setting (mA) for Column
OH
24, 20, 16, 12, 8, 4
24, 20, 16, 12, 8, 4
/ I
12, 10, 8, 6, 4, 2
OL
12, 10, 8, 6, 4
12, 10, 8, 6, 4
12, 10, 8, 6, 4
20, 18, 16, 8
16, 12, 8, 4
20, 18, 16
20, 18, 16
24, 20, 16
Current Strength
8, 6, 4, 2
I/O Pins
12, 8
Stratix II GX Device Handbook, Volume 1
Note (1)
Stratix II GX Architecture
I
OH
Setting (mA) for Row
/ I
OL
12, 10, 8, 6, 4
10, 8, 6, 4
Current Strength
8, 6, 4, 2
I/O Pins
12, 8, 4
12, 8, 4
8, 6, 4
12, 8
8, 4
4, 2
16
2–125