Specifications of WM8310GEB/V
Supply Voltage
7V
No. Of Step-down Dc - Dc Converters
4
No. Of Ldo Regulators
11
Digital Ic Case Style
BGA
No. Of Pins
169
No. Of Regulated Outputs
13
Operating Temperature Range
-40°C To
Rohs Compliant
Yes
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
- Current page: 180 of 284
- Download datasheet (2Mb)
WM8310
REGISTER
R16402
(4012h)
Interrupt
Status 2
Register 4012h Interrupt Status 2
w
ADDRESS
BIT
15
14
13
12
11
10
9
8
7
6
5
4
2
1
0
CHG_TO_EINT
CHG_MODE_E
OTP_ERR_EIN
PS_ON_WAKE
OTP_CMD_EN
PS_POR_EINT
CHG_BATT_H
CHG_BATT_C
CHG_START_
CHG_BATT_F
CHG_OV_EIN
PS_SLEEP_O
CHG_END_EI
OLD_EINT
CS2_EINT
CS1_EINT
AIL_EINT
OT_EINT
FF_EINT
LABEL
D_EINT
_EINT
EINT
INT
NT
T
T
DEFAULT
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Battery Hot interrupt
(Rising Edge triggered)
Note: Cleared when a ‘1’ is written.
Battery Cold interrupt
(Rising Edge triggered)
Note: Cleared when a ‘1’ is written.
Battery Fail interrupt
(Rising Edge triggered)
Note: Cleared when a ‘1’ is written.
Battery Overvoltage interrupt
(Rising Edge triggered)
Note: Cleared when a ‘1’ is written.
Battery Charge End interrupt (End of Charge Current
threshold reached)
(Rising Edge triggered)
Note: Cleared when a ‘1’ is written.
Battery Charge Timeout interrupt (Charger Timer has
expired)
(Rising Edge triggered)
Note: Cleared when a ‘1’ is written.
Battery Charge Mode interrupt (Charger Mode has
changed)
(Rising Edge triggered)
Note: Cleared when a ‘1’ is written.
Battery Charge Start interrupt (Charging has started)
(Rising Edge triggered)
Note: Cleared when a ‘1’ is written.
Current Sink 2 interrupt
(Rising Edge triggered)
Note: Cleared when a ‘1’ is written.
Current Sink 1 interrupt
(Rising Edge triggered)
Note: Cleared when a ‘1’ is written.
OTP / DBE Command End interrupt
(Rising Edge triggered)
Note: Cleared when a ‘1’ is written.
OTP / DBE Command Fail interrupt
(Rising Edge triggered)
Note: Cleared when a ‘1’ is written.
Power On Reset interrupt
(Rising Edge triggered)
Note: Cleared when a ‘1’ is written.
SLEEP or OFF interrupt (Power state transition to
SLEEP or OFF states)
(Rising Edge triggered)
Note: Cleared when a ‘1’ is written.
ON or WAKE interrupt (Power state transition to ON
state)
(Rising Edge triggered)
Note: Cleared when a ‘1’ is written.
DESCRIPTION
PP, December 2009, Rev 3.0
REFER TO
Pre-Production
180
Related parts for WM8310GEB/V
Image
Part Number
Description
Manufacturer
Datasheet
Request
R
![WM8310](/images/no-image3.png)
Part Number:
Description:
Processor Power Management Subsystem
Manufacturer:
Wolfson Microelectronics plc
Datasheet:
![WM9712LEFL](/images/manufacturer_photos/0/7/716/wolfson_microelectronics_tmb.jpg)
Part Number:
Description:
Manufacturer:
Wolfson Microelectronics
Datasheet: