WM8310GEB/V Wolfson Microelectronics, WM8310GEB/V Datasheet - Page 86

no-image

WM8310GEB/V

Manufacturer Part Number
WM8310GEB/V
Description
POWER MANAGEMENT SUBSYSTEM, 169BGA
Manufacturer
Wolfson Microelectronics
Datasheet

Specifications of WM8310GEB/V

Supply Voltage
7V
No. Of Step-down Dc - Dc Converters
4
No. Of Ldo Regulators
11
Digital Ic Case Style
BGA
No. Of Pins
169
No. Of Regulated Outputs
13
Operating Temperature Range
-40°C To
Rohs Compliant
Yes
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
WM8310
w
R16520 (4088h)
LDO11 SLEEP
Control
Table 40 LDO Regulator 11 Control
15.12.5 EXTERNAL POWER ENABLE (EPE) CONTROL
The register controls for configuring the External Power Enable (EPE) outputs are defined in Table
41.
Note that the EPE1_ON_SLOT and EPE2_ON_SLOT fields may also be stored in the integrated
OTP memory. See Section 14 for details.
R16486 (4066h)
EPE1 Control
ADDRESS
ADDRESS
15:13
15:13
12:11
BIT
BIT
3:0
8
LDO11_SLP
_SLOT [2:0]
LDO11_SLP
_VSEL [3:0]
EPE1_ON_S
LOT [2:0]
EPE1_HWC
_SRC [1:0]
EPE1_HWC
ENA
LABEL
LABEL
DEFAULT
DEFAULT
000
000
00
0
LDO11 SLEEP Slot select
000 = SLEEP voltage / operating mode
transition in Timeslot 5
001 = Disable in Timeslot 5
010 = Disable in Timeslot 4
011 = Disable in Timeslot 3
100 = Disable in Timeslot 2
101 = Disable in Timeslot 1
110 = SLEEP voltage / operating mode
transition in Timeslot 3
111 = SLEEP voltage / operating mode
transition in Timeslot 1
If LDO11 is assigned to a Hardware
Enable Input, then codes 001-101 select
in which timeslot the regulator enters its
SLEEP condition.
LDO11 SLEEP Voltage select
0.80V to 1.55V in 50mV steps
0h = 0.80V
1h = 0.85V
2h = 0.90V
Eh = 1.50V
Fh = 1.55V
EPE1 ON Slot select
000 = Do not enable
001 = Enable in Timeslot 1
010 = Enable in Timeslot 2
011 = Enable in Timeslot 3
100 = Enable in Timeslot 4
101 = Enable in Timeslot 5
110 = Controlled by Hardware Enable 1
111 = Controlled by Hardware Enable 2
EPE1 Hardware Control Source
00 = Disabled
01 = Hardware Control 1
10 = Hardware Control 2
11 = Hardware Control 1 or 2
EPE1 Hardware Control Enable
0 = EPE1 is controlled by EPE1_ENA
(Hardware Control input(s) are ignored)
1 = EPE1 is controlled by HWC inputs
(Hardware Control input(s) force EPE1
to be de-asserted)
PP, December 2009, Rev 3.0
DESCRIPTION
DESCRIPTION
Pre-Production
86

Related parts for WM8310GEB/V