Specifications of WM8310GEB/V

Supply Voltage
7V
No. Of Step-down Dc - Dc Converters
4
No. Of Ldo Regulators
11
Digital Ic Case Style
BGA
No. Of Pins
169
No. Of Regulated Outputs
13
Operating Temperature Range
-40°C To
Rohs Compliant
Yes
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Pre-Production
Register 4061h DC3 Control 2
REGISTER
R16482
(4062h) DC3
ON Config
Register 4062h DC3 ON Config
REGISTER
R16483
(4063h) DC3
SLEEP
Control
w
ADDRESS
ADDRESS
15:13
15:13
BIT
BIT
9:8
6:2
1:0
9:8
DC3_SLP_SLO
DC3_ON_MOD
DC3_ON_SLO
DC3_ON_VSE
DC3_ON_VSE
DC3_SLP_MO
LABEL
LABEL
E[1:0]
T[2:0]
L[4:0]
L[1:0]
T[2:0]
DEFAULT
DEFAULT
0_0000
000
000
01
00
11
DC-DC3 ON Slot select
000 = Do not enable
001 = Enable in Timeslot 1
010 = Enable in Timeslot 2
011 = Enable in Timeslot 3
100 = Enable in Timeslot 4
101 = Enable in Timeslot 5
110 = Controlled by Hardware Enable 1
111 = Controlled by Hardware Enable 2
DC-DC3 ON Operating Mode
00 = Forced Continuous Conduction Mode
01 = Continuous / Discontinuous Conduction with
Pulse-Skipping
10 = LDO Mode
11 = Hysteretic Mode
DC-DC3 ON Voltage select
DC3_ON_VSEL[6:0] selects the DC-DC3 output
voltage from 0.85V to 3.4V in 25mV steps.
DC3_ON_VSEL[6:2] also exist in DBE/OTP memory,
controlling the voltage in 100mV steps.
DC3_ON_VSEL[6:0] is coded as follows:
00h = 0.85V
01h = 0.875V
65h = 3.375V
66h to 7Fh = 3.4V
DC3 ON Voltage select
DC3_ON_VSEL[6:0] selects the DC3 output voltage
from 0.85V to 3.4V in 25mV steps.
See DC3_ON_VSEL[6:2] for definition.
DC-DC3 SLEEP Slot select
000 = SLEEP voltage / operating mode transition in
Timeslot 5
001 = Disable in Timeslot 5
010 = Disable in Timeslot 4
011 = Disable in Timeslot 3
100 = Disable in Timeslot 2
101 = Disable in Timeslot 1
110 = SLEEP voltage / operating mode transition in
Timeslot 3
111 = SLEEP voltage / operating mode transition in
Timeslot 1
If DC-DC3 is assigned to a Hardware Enable Input,
then codes 001-101 select in which timeslot the
converter enters its SLEEP condition.
DC-DC3 SLEEP Operating Mode
DESCRIPTION