ST72321AR6-Auto STMicroelectronics, ST72321AR6-Auto Datasheet - Page 179

no-image

ST72321AR6-Auto

Manufacturer Part Number
ST72321AR6-Auto
Description
8-bit MCU for automotive with 32 Kbyte Flash, 10-bit ADC, timers, SPI, SCI and I2C interfaces
Manufacturer
STMicroelectronics
Datasheet

Specifications of ST72321AR6-Auto

Hdflash Endurance
100 cycles, data retention 20 years
Clock Sources
crystal/ceramic resonator oscillators, internal RC oscillator and bypass for external clock
4 Power Saving Modes
Halt, Active Halt, Wait and Slow
ST72321xx-Auto
18.1.2
18.1.3
18.1.4
Immediate
Immediate instructions have 2 bytes. The first byte contains the opcode and the second byte
contains the operand value.
Table 99.
Direct
In Direct instructions, the operands are referenced by their memory address.
The direct addressing mode consists of two submodes:
Direct (short)
The address is a byte, thus requires only one byte after the opcode, but only allows 00 - FF
addressing space.
Direct (long)
The address is a word, thus allowing 64 Kbyte addressing space, but requires 2 bytes after
the opcode.
Indexed (no offset, short, long)
In this mode, the operand is referenced by its memory address, which is defined by the
unsigned addition of an index register (X or Y) with an offset.
The indexed addressing mode consists of three submodes:
Indexed (no offset)
There is no offset, (no extra byte after the opcode), and allows 00 - FF addressing space.
Indexed (short)
The offset is a byte, thus requires only one byte after the opcode and allows 00 - 1FE
addressing space.
Indexed (long)
The offset is a word, thus allowing 64 Kbyte addressing space and requires 2 bytes after the
opcode.
LD
CP
BCP
AND, OR, XOR
ADC, ADD, SUB, SBC
Immediate instructions
Instruction
Doc ID 13829 Rev 1
Load
Compare
Bit Compare
Logical Operations
Arithmetic Operations
Function
Instruction set
179/243