Z8S180 Zilog., Z8S180 Datasheet - Page 147

no-image

Z8S180

Manufacturer Part Number
Z8S180
Description
ENHANCED Z180 MICROPROCESSOR
Manufacturer
Zilog.
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
Z8S18010FEC
Manufacturer:
Zilog
Quantity:
10 000
Part Number:
Z8S18010FEC00TR
Manufacturer:
Zilog
Quantity:
10 000
Part Number:
Z8S18010FEG
Manufacturer:
Zilog
Quantity:
10 000
Part Number:
Z8S18010FSC
Manufacturer:
Zilog
Quantity:
10 000
Part Number:
Z8S18010FSC00TR
Manufacturer:
Zilog
Quantity:
10 000
Part Number:
Z8S18010FSCZ180
Manufacturer:
ZILOG
Quantity:
748
Part Number:
Z8S18010FSG
Manufacturer:
Zilog
Quantity:
426
Part Number:
Z8S18010PSG
Manufacturer:
Zilog
Quantity:
48
Part Number:
Z8S18010VEC
Manufacturer:
ZILOG
Quantity:
12 388
Part Number:
Z8S18010VSC
Manufacturer:
ZILOG
Quantity:
250
132
ASCI Control Register B 0 (CNTLB0: 02H)
ASCI Control Register B 1 (CNTLB1: 03H)
UM005001-ZMP0400
Bit
Bit/Field
R/W
Reset
Note: R = Read W = Write X = Indeterminate ? = Not Applicable
Bit
Position Bit/Field R/W
7
6
Z 8018x Fam il y
M PU Us e r M anual
MPBT
MP
MPBT
R/W
7
X
R/W
R/W
R/W
MP
6
0
Value
CTS/PS
R/W
5
0
Description
Multiprocessor Bit Transmit — When multiprocessor
communication format is selected (MP bit is 1), MPBT is
used to specify the MPB data bit for transmission. If
MPBT is 1, then MPB = 1 is transmitted. If MPBT is 0,
then MPBT = 0 is transmitted. MPBT state is undefined
during and after RESET.
Multiprocessor Mode — When MP is set to 1, the data
format is configured for multiprocessor mode based on
the MOD2 (number of data bits) and MOD0 (number of
stop bits) bits in CNTLA. The format is as follows.
Start bit + 7 or 8 data bits + MPB bit + 1 or 2 stop bits
Multiprocessor (MP = 1) format has no provision for
parity. If MP is 0, the data format is based on MOD0
MOD1, MOD2, and may include parity. The MP bit is
cleared to 0 during RESET.
R/W
PE0
4
0
R/W
DR
3
0
R/W
SS2
2
1
R/W
SS1
1
1
R/W
SS0
0
1