NAND02GW3B2CN1F STMICROELECTRONICS [STMicroelectronics], NAND02GW3B2CN1F Datasheet - Page 27

no-image

NAND02GW3B2CN1F

Manufacturer Part Number
NAND02GW3B2CN1F
Description
1 Gbit, 2 Gbit, 2112 Byte/1056 Word Page, 1.8V/3V, NAND Flash Memory
Manufacturer
STMICROELECTRONICS [STMicroelectronics]
Datasheet
NAND01G-B2B, NAND02G-B2C
6.4
Copy Back Program
The Copy Back Program operation is used to copy the data stored in one page and
reprogram it in another page.
The Copy Back Program operation does not require external memory and so the operation
is faster and more efficient because the reading and loading cycles are not required. The
operation is particularly useful when a portion of a block is updated and the rest of the block
needs to be copied to the newly assigned block.
If the Copy Back Program operation fails an error is signalled in the Status Register.
However as the standard external ECC cannot be used with the Copy Back Program
operation bit error due to charge loss cannot be detected. For this reason it is recommended
to limit the number of Copy Back Program operations on the same data and or to improve
the performance of the ECC.
The Copy Back Program operation requires four steps:
1.
2.
3.
To see the Data Input cycle for modifying the source page and an example of the Copy Back
Program operation refer to
A data input cycle to modify a portion or a multiple distant portion of the source page, is
shown in
Table 11.
Table 12.
1 Gbit
2 Gbit
1 Gbit
2 Gbit
The first step reads the source page. The operation copies all 1056 Words/ 2112 Bytes
from the page into the Data Buffer. It requires:
When the device returns to the ready state (Ready/Busy High), the next bus write cycle
of the command is given with the 4 or 5 bus cycles to input the target page address
(see
for the Source and Target pages.
Then the confirm command is issued to start the P/E/R Controller.
Figure
one bus write cycle to setup the command
4 or 5 bus write cycles to input the source page address (see
one bus write cycle to issue the confirm command code
Table 6
Density
Density
Copy Back Program x8 Addresses
Copy Back Program x16 Addresses
12.
and
Table
Figure
7). Refer to
11.
Table 11
Same Address for Source and Target Pages
Same Address for Source and Target Pages
for the addresses that must be the same
no constraint
no constraint
A28
A27
Table 6
Device operations
and
Table
27/62
7)