C8051F060-TB Silicon Laboratories Inc, C8051F060-TB Datasheet - Page 194

BOARD PROTOTYPING W/C8051F060

C8051F060-TB

Manufacturer Part Number
C8051F060-TB
Description
BOARD PROTOTYPING W/C8051F060
Manufacturer
Silicon Laboratories Inc
Type
MCUr
Datasheets

Specifications of C8051F060-TB

Contents
Board
Processor To Be Evaluated
C8051F06x
Interface Type
USB
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
For Use With/related Products
C8051F060
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
C8051F060/1/2/3/4/5/6/7
17.6. Timing
The timing parameters of the External Memory Interface can be configured to enable connection to
devices having different setup and hold time requirements. The Address Setup time, Address Hold time, /
RD and /WR strobe widths, and in multiplexed mode, the width of the ALE pulse are all programmable in
units of SYSCLK periods through EMI0TC, shown in Figure 17.6, and EMI0CF[1:0].
The timing for an off-chip MOVX instruction can be calculated by adding 4 SYSCLK cycles to the timing
parameters defined by the EMI0TC register. Assuming non-multiplexed operation, the minimum execution
time for an off-chip XRAM operation is 5 SYSCLK cycles (1 SYSCLK for /RD or /WR pulse + 4 SYSCLKs).
For multiplexed operations, the Address Latch Enable signal will require a minimum of 2 additional SYS-
CLK cycles. Therefore, the minimum execution time for an off-chip XRAM operation in multiplexed mode
is 7 SYSCLK cycles (2 for /ALE + 1 for /RD or /WR + 4). The programmable setup and hold times default
to the maximum delay settings after a reset.
194
Bits7-6:
Bits5-2:
Bits1-0:
EAS1
R/W
Bit7
EAS1-0: EMIF Address Setup Time Bits.
00: Address setup time = 0 SYSCLK cycles.
01: Address setup time = 1 SYSCLK cycle.
10: Address setup time = 2 SYSCLK cycles.
11: Address setup time = 3 SYSCLK cycles.
EWR3-0: EMIF /WR and /RD Pulse-Width Control Bits.
0000: /WR and /RD pulse width = 1 SYSCLK cycle.
0001: /WR and /RD pulse width = 2 SYSCLK cycles.
0010: /WR and /RD pulse width = 3 SYSCLK cycles.
0011: /WR and /RD pulse width = 4 SYSCLK cycles.
0100: /WR and /RD pulse width = 5 SYSCLK cycles.
0101: /WR and /RD pulse width = 6 SYSCLK cycles.
0110: /WR and /RD pulse width = 7 SYSCLK cycles.
0111: /WR and /RD pulse width = 8 SYSCLK cycles.
1000: /WR and /RD pulse width = 9 SYSCLK cycles.
1001: /WR and /RD pulse width = 10 SYSCLK cycles.
1010: /WR and /RD pulse width = 11 SYSCLK cycles.
1011: /WR and /RD pulse width = 12 SYSCLK cycles.
1100: /WR and /RD pulse width = 13 SYSCLK cycles.
1101: /WR and /RD pulse width = 14 SYSCLK cycles.
1110: /WR and /RD pulse width = 15 SYSCLK cycles.
1111: /WR and /RD pulse width = 16 SYSCLK cycles.
EAH1-0: EMIF Address Hold Time Bits.
00: Address hold time = 0 SYSCLK cycles.
01: Address hold time = 1 SYSCLK cycle.
10: Address hold time = 2 SYSCLK cycles.
11: Address hold time = 3 SYSCLK cycles.
EAS0
R/W
Bit6
Figure 17.6. EMI0TC: External Memory Timing Control
ERW3
R/W
Bit5
EWR2
R/W
Bit4
Rev. 1.2
EWR1
R/W
Bit3
EWR0
R/W
Bit2
EAH1
R/W
Bit1
SFR Address:
SFR Page:
EAH0
R/W
Bit0
0xA1
0
Reset Value
11111111