DP83865-EB National Semiconductor, DP83865-EB Datasheet - Page 29

no-image

DP83865-EB

Manufacturer Part Number
DP83865-EB
Description
BOARD EVALUATION DP83865
Manufacturer
National Semiconductor
Datasheet

Specifications of DP83865-EB

Main Purpose
Interface, Ethernet
Utilized Ic / Part
DP83865
Lead Free Status / RoHS Status
Not applicable / Not applicable
2.0 Register Block
This register contains the next page information sent by its Link Partner during Auto-Negotiation.
15:13
10:0
Bit
Bit
11
12
11
10
Table 11. Auto-Negotiation Next Page Receive Register (ANNPRR) address 0x08
Repeater / DTE
Manual Config.
Master / Slave
Master / Slave
Config. Value
CODE[10:0]
Test Mode
Bit Name
Bit Name
TOG_RX
Enable
(Continued)
Table 12. 1000BASE-T Control Register (1KTCR) address 0x09
000_0000>, RO
STRAP[0], RW Advertise Device Type: Multi or single port
11’b<000_0
Default
Default
0, RW
0, RW
0, RW
0, RO
Toggle:
1 = Value of toggle bit in previously transmitted Link Code Word
was logic 0.
0 = Value of toggle bit in previously transmitted Link Code Word
was logic 1.
Toggle is used by the Arbitration function within Auto-Negotiation
to ensure synchronization with the Link Partner during Next Page
exchange. This bit shall always take the opposite value of the
Toggle bit in the previously exchanged Link Code Word.
This field represents the code field of the next page transmission.
If the MP bit is set (bit 13 of this register), then the code shall be
interpreted as a "Message Page”, as defined in annex 28C of
IEEE 802.3u. Otherwise, the code shall be interpreted as an "Un-
formatted Page”, and the interpretation is application specific.
The default value of the CODE represents a Reserved for future
use as defined in Annex 28C of IEEE 802.3u.
Test Mode Select:
See IEEE 802.3ab section 40.6.1.1.2 “Test modes” for more in-
formation. Output for TX_TCLK when in Test Mode is on pin 6.
Enable Manual Master / Slave Configuration:
1 = Enable Manual Master/Slave Configuration control.
0 = Disable Manual Master/Slave Configuration control.
Using the manual configuration feature may prevent the PHY
from establishing link in 1000Base-T mode if a conflict with the
link partner’s setting exists.
Manual Master / Slave Configuration Value:
1 = Set PHY as MASTER when register 09h bit 12 = 1.
0 = Set PHY as SLAVE when register 09h bit 12 = 1.
Using the manual configuration feature may prevent the PHY
from establishing link in 1000Base-T mode if a conflict with the
link partner’s setting exists.
1 = Repeater or Switch.
0 = DTE.
(The default value of this bit is = to the strap value of pin 94 during
reset/power-on IF Auto-Negotiation is enabled.)
29
bit 15
1
0
0
0
0
bit 14
0
1
1
0
0
bit 13
0
1
0
1
0
Description
Description
Test Mode Selected
= Test Mode 4
= Test mode 3
= Test Mode 2
= Test Mode 1
= Normal Operation
www.national.com